Connectrix MDS: MDS 9706 veya 9710'da "bootflash meşgul; bootflash'ı monte ederken seg hatası"

Summary: Kullanıcı, NX-OS 6.2.19'dan 8.1.1'e yükselttikten sonra artık "bootflash://sup-standby" öğesini görene kadar hiçbir şey göremektedir.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

NX-OS 6.2.19'dan 8.1.1'e yükseltme.

Yükseltmeden sonra kullanıcı artık "bootflash://sup-standby"i görene bootflash://sup-standby.

Aşağıdaki gibi görülür:
MDS1# dir bootflash:
bootflash:///
bootflash://module-5/
bootflash://sup-1/
bootflash://sup-active/
bootflash://sup-local/ 
Çalışan bir anahtarda aşağıdakiler gösterilmektedir:
MDS2# dir bootflash:
bootflash:///
bootflash://module-6/
bootflash://sup-2/
bootflash://sup-local/
bootflash://sup-standby/
bootflash://module-5/
bootflash://sup-1/
bootflash://sup-active/
bootflash://sup-remote/    <---------------
Sorunun diğer belirtileri aşağıdaki gibi olabilir:
  • ISSU/D, aşağıdaki hata mesajıyla başarısız oluyor:
Pre-upgrade check failed. Return code 0x4093007E (Issue cannot be done, bootflash is busy). 'segmentation fault' error messages when issuing `sys health check bootflash`:

switch# sys health check bootflash Unmount successful... Checking any file system errors...Please be patient... /isanboot/sbin/format-bootflash: line 75: 7598 Segmentation fault $SUDO $E2FSCK -n -v $@ > /dev/null 2> /dev/null done. 
Remounting bootflash .../isanboot/sbin/format-bootflash: line 62: 7600 Segmentation fault $SUDO /bin/mount $MNT_BOOTFLASH_DIR Failed to mount bootflash bootflash on the affected supervisor is not available switch# dir no such file or directory (invalid server) 
Logging log outputs: %BOOTVAR-2-AUTOCOPY_STANDBY_MOUNT_FAILED: Autocopy failed to access standby file system via NFS mount.Please, copy the boot images manually to standby bootflash. %SYSMGR-2-LAST_CORE_BASIC_TRACE: : PID 6688 with message non-sysmgr(non-sysmgr) crashed, core will be saved . Core file also generated: 
`show cores` Module  Instance  Process-name     PID       Date(Year-Month-Day Time) ------  --------  ---------------  --------  ------------------------- 5       1         non-sysmgr       6688      2017-10-08 07:29:07

Cause

Sorun, Cisco CSCvb93701'den aşağıdaki şekilde tespit edilmiştir:
ISSU/D fails on MDS 9706/9710 with 'bootflash busy' error; seg fault while mounting bootflash
CSCvb93701 (see also CSCvf99665)
Belgelenmiş Cisco sorununa göre:
The system is only affected if it was previously running one of the following NX-OS releases: 6.2(17) - 6.2(19) 7.3(0)D1(1) - 7.3(1)D1(1) 7.3(0)DY(1) - 7.3(1)DY(1) This issue does not apply to any other NX-OS releases on MDS 9706 and 9710 platforms. It does not occur on the MDS 9718 platform.

Resolution

Geçi -ci çözüm:
Yönetim arabirimindeki IPv6 geçersiz alt ağ bu soruna neden olur.
switch13# show interface mgmt0
mgmt0 is up
    Hardware is GigabitEthernet
    Address is 2cab.ebfd.4386
    Internet address(es):
        10.8.96.223/23
        ::148.125.166.255/0      <--- "0" indicates an invalid subnet
        fe80::2eab:ebff:fefd:4386/64

Kurtarma yardımı için Dell Teknik Destek ile iletişime geçin.

Affected Products

Connectrix MDS-9710

Products

Connectrix MDS-9706, Connectrix MDS-9710
Article Properties
Article Number: 000052402
Article Type: Solution
Last Modified: 21 Sept 2023
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.