NetWorker:v9.0 VMwareジョブのクローンをCloudBoostデバイスに作成できない

Summary: CloudBoostへのVMware vProxyセーブセットのクローン作成が失敗します。不正なセーブセットID、作業アイテムなし、エラー:サポートされていないノードを含むプール。原因:ノード バージョン9.1。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 

VMwareバックアップ(vProxyバックアップ)セーブセットのCloudBoostデバイスへのクローン作成が失敗します。

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

障害発生時のデーモン ログ <mm/dd/yyyy hh:mm:ss meridiem> を確認すると、次のメッセージが見つかります。

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Cause

機能拡張のリクエスト。既知の問題:NW-I-404: NetWorker:vProxyセーブセットのCloudBoostアプライアンスへのクローン作成。

Resolution

製品管理部では、この機能拡張リクエストを調査中です。リクエストはまだ進行中です。カスタマー サポート センターに連絡し、この記事番号をお伝えください。

回避策: NetWorker 9.0.1以降のデータ ゾーンで外部ストレージ ノードを構成します。『NetWorker 9.1 CloudBoost 2.1統合ガイド』の「NetWorker 9.1: Configuring a device by using an external storage node for CloudBoost」を参照してください。