Kloning av VMware-sikkerhetskopier (vProxy-sikkerhetskopiering) av lagringssett til en CloudBoost-enhet mislykkes.
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
Gjennomgang av daemon loggen på det tidspunktet <mm / dd / yyyy hh:mm: ss meridiem> av feilen finner meldingen:
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Cause
Forespørsel om forbedring. Kjent problem: NW-I-404: NetWorker: Kloning av vProxy-lagringssett til et CloudBoost-apparat.
Resolution
Product Management undersøker denne forespørselen om forbedring. Forespørselen pågår fortsatt. Kontakt kundestøttesenteret for å få hjelp og oppgi dette artikkelnummeret.
OMGÅ: Med en NetWorker 9.0.1-datasone eller nyere kan du konfigurere en ekstern lagringsnode, se "NetWorker 9.1 CloudBoost 2.1 Integration Guide" i delen "NetWorker 9.1: Konfigurere en enhet ved hjelp av en ekstern lagringsnode for CloudBoost".
OMGÅ: Med en NetWorker 9.0.1-datasone eller nyere kan du konfigurere en ekstern lagringsnode, se "NetWorker 9.1 CloudBoost 2.1 Integration Guide" i delen "NetWorker 9.1: Konfigurere en enhet ved hjelp av en ekstern lagringsnode for CloudBoost".