NetWorker: v9.0 Det går inte att klona VMware-jobb till en CloudBoost-enhet

Summary: Det går inte att klona VMware vProxy-sparade uppsättningar till CloudBoost. Felaktiga saveset-ID:n, inga arbetsobjekt, fel: pool med noder som inte stöds; Orsak: Nod version 9.1.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 

Det går inte att klona sparuppsättningar för VMware-säkerhetskopior (vProxy-säkerhetskopiering) till en CloudBoost-enhet.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

Granskning av daemonloggen vid tidpunkten <mm/dd/yyyy hh:mm:ss meridiem> av felet hittar meddelandet:

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Cause

Begäran om förbättring. Känt problem: NW-I-404: NetWorker: Klona vProxy-sparuppsättningar till en CloudBoost-enhet.

Resolution

Produkthantering undersöker denna begäran om förbättring. Begäran är fortfarande under behandling. Kontakta kundsupportcentret för hjälp och ange det här artikelnumret.

KRINGGÅ: Med en NetWorker 9.0.1 eller senare datazon, konfigurera en extern lagringsnod, se "NetWorker 9.1 CloudBoost 2.1 Integration Guide" avsnittet "NetWorker 9.1: Konfigurera en enhet med hjälp av en extern lagringsnod för CloudBoost".

Affected Products

Cloud Backup & Protection, NetWorker
Article Properties
Article Number: 000065416
Article Type: Solution
Last Modified: 04 Dec 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.