NetWorker:v9.0 无法将 VMware 作业克隆到 CloudBoost 设备
Summary: 将 VMware vProxy 存储集克隆到 CloudBoost 失败。存储集 ID 错误,无工作项目,错误:具有不受支持的节点的池;原因:节点版本 9.1。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
将 VMware 备份(vProxy 备份)存储集克隆到 CloudBoost 设备失败。
mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid <SSID> mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. . mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list. mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS! mm/dd/yyyy hh:mm:ss meridiem No valid backend job mm/dd/yyyy hh:mm:ss meridiem [ORIGINAL REQUESTED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/; mm/dd/yyyy hh:mm:ss meridiem [CLONE SKIPPED SAVESETS] mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>; mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1 mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.
在失败的 mm/dd/yyyy hh:mm:ss meridiem> 期间检视守护程序日志<,找到以下消息:
71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>' 165718 mm/dd/yyyy hh:mm:ss meridiem 5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>. 71193 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '. 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed 38758 mm/dd/yyyy hh:mm:ss meridiem 0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed 89017 mm/dd/yyyy hh:mm:ss meridiem 1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
Cause
请求增强功能。已知问题:NW-I-404:NetWorker:将 vProxy 存储集克隆到 CloudBoost 设备。
Resolution
产品管理部门正在调查此增强请求。该请求仍在进行中。请联系客户支持中心寻求帮助,并引用本文编号。
解决方法:使用 NetWorker 9.0.1 或更高版本数据区,配置外部存储节点,请参阅“NetWorker 9.1 CloudBoost 2.1 集成指南”中的“NetWorker 9.1:使用外部存储节点为 CloudBoost 配置设备”。
解决方法:使用 NetWorker 9.0.1 或更高版本数据区,配置外部存储节点,请参阅“NetWorker 9.1 CloudBoost 2.1 集成指南”中的“NetWorker 9.1:使用外部存储节点为 CloudBoost 配置设备”。
Affected Products
Cloud Backup & Protection, NetWorkerArticle Properties