PowerProtect:無法新增 Data Domain 至 PowerProtect Data Manager 19.14

Summary: 本文解決了 Data Domain 無法新增至 PowerProtect Data Manager 19.14 版的問題。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Data Domain 未新增至 PowerProtect Data Manager 19.14,並出現以下錯誤。
 
無法新增 Data Domain - 交握失敗
圖 1:無法新增 Data Domain - 交握失敗

Data Domain SMS 記錄 (sms.info) 顯示下列錯誤訊息: 
WARNING: smu_services_verify_dhparam_file:454 DH PARAMETER file "/root/certs/dhparam.pem" doesn't exist.
ERROR: _sms_init_ssl_server_context:496:Error loading DH parameter file, DH parameter file doesn't exist

Cause

只有在 Data Domain 中有檔案 /root/certs/dhparam.pem 時,PowerProtect Data Manager 才能完成 SSL 交握。

Resolution

請聯絡 Dell PowerProtect Data Manager 支援,重新建立 Data Domain 中的檔案 /root/certs/dhparam.pem。
Article Properties
Article Number: 000216893
Article Type: Solution
Last Modified: 05 Sept 2023
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.