Connectrix - MDS 系列 Cisco:如何使用 CLI 创建端口通道

Summary: 如何使用 CLI 在 Cisco 交换机上创建端口通道。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

如何在 Cisco 交换机上创建端口通道。
 

步骤 1:在交换机 1 上:

  1. 创建端口通道。

    switch1# config terminal
    Enter configuration commands, one per line, ending with CNTL/Z.
    switch1(config)# interface fc1/1, fc2/1
    switch1(config-if)# channel-group 2


    FC1/1、FC2/1 已添加到端口通道 2 并已禁用。

    在端口通道另一端的交换机上执行相同的作,然后在两端执行“no shutdown”以使其恢复正常。

    switch1(config-if)# switchport description "To switch2 PortChannel2"
     
  2. 在交换机 1 上启用中继 (TE) 并设置 VSAN 允许列表。

    switch1# config terminal
    switch1(config)# int port-channel 2
    switch1(config-if)# switchport trunk mode on
    switch1(config-if)# switchport trunk allowed vsan 1
    switch1(config-if)# switchport trunk allowed vsan add 10

 

步骤 2:在交换机 2 上:

  1. 在交换机 2 上创建端口通道,包括设置描述。

    switch2# config terminal
    Enter configuration commands, one per line, ending with CNTL/Z.
    switch2(config)# interface fc1/1, fc2/1
    switch2(config-if)# channel-group 2


    FC1/1、FC2/1 已添加到端口通道 2 并已禁用。

    在端口通道另一端的交换机上执行相同的作,然后在两端执行“no shutdown”以使其恢复正常。

    switch2(config-if) # switchport description "To switch1 PortChannel2"
     
  2. 在交换机 1 上启用中继 (TE) 并设置 VSAN 允许列表。

    switch2# config terminal
    switch2(config)# int port-channel 2
    switch2(config-if)# switchport trunk mode on
    switch2(config-if)# switchport trunk allowed vsan 1
    switch2(config-if)# switchport trunk allowed vsan add 10


步骤 3:启用接口以启动端口通道:

  1. Switch1:

    switch1# config terminal
    Enter configuration commands, one per line, ending with CNTL/Z.
    switch1(config)# interface fc1/1, fc2/1
    switch1(config-if)# no shut

     
  2. Switch2:

    switch2# config terminal
    Enter configuration commands, one per line, ending with CNTL/Z.
    switch2(config)# interface fc1/1, fc2/1
    switch2(config-if)# no shut

 

步骤 4:验证端口通道是否已启动:

switch1# show interface port-channel 2
port-channel 2 is trunking
Port description is To switch2 PortChannel2
Hardware is Fibre Channel
Port WWN is 24:02:00:0c:85:e9:d2:c0
Admin port mode is E, trunk mode is on
Port mode is TE
Port vsan is 1
Speed is 4 Gbps
Trunk vsans (admin allowed and active) (1,10)

Trunk vsans (up) (1,10)
Trunk vsans (isolated) ()
Trunk vsans (initializing) ()
5 minutes input rate 64 bits/sec, 8 bytes/sec, 0 frames/sec
5 minutes output rate 56 bits/sec, 7 bytes/sec, 0 frames/sec 78296342 frames input, 72311141128 bytes 0 discards, 0 errors
0 CRC, 0 unknown class
0 too long, 0 too short
56299070 frames output, 26061293700 bytes
0 discards, 0 errors
0 input OLS, 2 LRR, 0 NOS, 0 loop inits
4 output OLS, 2 LRR, 0 NOS, 0 loop inits
Member[1] : fc1/2
Member[2] : fc2/1

 

Additional Information

端口通道允许将多个 FC 或 FCIP 链路聚合为单个速度更高、容错的 FC 或 FCIP ISL。就配置而言,它具有与单链路 FC 或 FCIP ISL 相同的配置选项。


有关详细信息,请参阅思科关于配置端口通道的文档。

请参阅此已发布的视频: