PowerFlex 3.X The Presentation Server Stops Logging Alerts In The UI
Summary: The Presentation Server stops logging alerts in the UI.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Symptoms
In this scenario, the Presentation Server (mgmt-server) is installed on an SDS node.
Events from the Primary MDM show the SDS on which the mgmt-server is installed on being placed in Maintenance Mode and rebooted.
2023-07-19 23:39:45.351000:0237719:MDM_CLI_CONF_COMMAND_RECEIVED INFO Command enter_maintenance_mode received, User: ': user-a'. [3246236] SDS: ID: 7fcf39320000000c; 2023-07-19 23:40:02.906000:0237721:SDS_DECOUPLED ERROR SDS: sds-03 (id: 7fcf39320000000c) decoupled. 2023-07-19 23:58:58.776000:0237726:SDS_RECONNECTED INFO SDS: sds-03 (ID 7fcf39320000000c) reconnected.
/var/log/messages show the node being rebooted.
Jul 19 23:47:27 sds-03 systemd-shutdownd: Shutting down at Wed 2023-07-19 23:48:27 BST (reboot)... When the node boots up, the mgmt-server service initiates but fails when attempting to start the Alert Manager service.
The scaleio.log from the mgmt-server may show the following errors.
2023-07-19 23:58:39,662 [main|INFO |com.emc.vxflexos.webui.backend.Server.main] Starting PowerFlex MGMT server...
2023-07-19 23:58:44,796 [main|INFO |com.emc.vxflexos.webui.backend.services.ServicesModule.lambda$null$1] Registering service AlertsManagerService to ServiceManager
2023-07-19 23:58:45,804 [AlertsManagerService STARTING|INFO |com.emc.vxflexos.webui.backend.services.alerts.AlertsManagerService.lambda$new$2] Alerts observable got subscribed
2023-07-19 23:58:45,811 [RxSingleScheduler-1|ERROR|com.emc.vxflexos.webui.backend.services.alerts.AlertsManagerService.onError] Error occurred:
java.util.ConcurrentModificationException: null
at java.util.HashMap.computeIfAbsent(HashMap.java:1135) ~[?:?]
at com.slimgears.util.autovalue.annotations.PropertyMeta$1.getAnnotation(PropertyMeta.java:130) ~[auto-value-utils-annotations-0.7.46.jar:?]
at com.slimgears.util.autovalue.annotations.PropertyMeta.hasAnnotation(PropertyMeta.java:76) ~[auto-value-utils-annotations-0.7.46.jar:?]
at com.slimgears.rxrepo.util.PropertyExpressions.lambda$mandatoryProperties$13(PropertyExpressions.java:267) ~[rxrepo-core-0.7.130.jar:?]
Impact
Alerts aren't shown in the UI.
Cause
Following a node reboot, the Presentation Server may not display alerts. This sporadic issue appears to be associated with timing or a race condition during the node's startup.
Resolution
To workaround the issue, restart the mgmt-server service to get the alerts back.
systemctl restart mgmt-server.service
Impacted Versions
PowerFlex 3.6.3 and below
Fixed In Version
PowerFlex 3.6.4
Affected Products
PowerFlex appliance connectivity, Ready Node SeriesProducts
PowerFlex rack, PowerFlex custom node, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R7625, PowerFlex appliance R640
, PowerFlex appliance R740XD, PowerFlex appliance R7525, PowerFlex appliance R840
...
Article Properties
Article Number: 000223655
Article Type: Solution
Last Modified: 03 Feb 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.