Instructions

Unisphere is designed to log into either SP and control the array.  Unisphere will ask for the 'peer' SP the first; and if you always accept Certificates it may not do so in the future.  However it is getting information from both SP's to display.
 
Thus for analyzer, it is designed to be started or stopped from either SP, and will be running for both.  There are exceptions if an SP is not responding when starting the analyzer.  In that case we stop all the anlayzer settings, restart the management server, then turn analyzer back on.
 
From either SP on Unisphere:
1- Turn on Statistics Logging under System ->System Properties on the General Tab
2- From the Data Logging window under System->Monitoring&Alerts->StatisticsforBlock->PerformanceDataLogging the following is done/seen.   Current status of logging data; start/stop data logging; change values of the polling interval.  This will be affective for BOTH SPs.
3- Confirm from the Retrieve Archives.  There you pick the SP you want to pull the logs from.  Each SP should have an archive file of approximately the same time.
It takes minimum of 10 polls to create a file so the first one cannot be there until 10x the polling rates' seconds setting.
 
From cli commands we can also see anlayzer.
These commands are mostly specific to the SP picked so it is recommended to check on each for best confirmation.
 
If you create a Security file for naviseccli on your PC, then the command can be shortened to below examples; I substituted "vnxa" or "vnxb" as the ipaddress.
Pick either the ipaddress of SPa or SPb to confirm at an SP level.
 
From the CS-Control station of a unified array, the format is "/nas/sbin/navicli -h <spa or spb> analyzer -xxxxxxx"
Here is the options list, followed by examples:
 
C:\>naviseccli -h vnxa analyzer -
Invalid Command. Invalid command line parameters.
usage:
  analyzer
    -set
        <-narinterval seconds>
        <-rtinterval seconds>
        <-nonstop | -logperiod days>
        <-periodicarchiving 0|1>
        <-default>
    -get
        <-narinterval>
        <-rtinterval>
        <-logperiod>
        <-periodicarchiving>
    -logging
        <-reset>
    -start
    -stop
    -status
    -archive
        <-list>
        <-path path>
        <-o>
        <-all | -file filenames>
        <-delete>
        <-new | -statusnew filename>
                               
naviseccli -h <vnxa/vnxb> analyzer -status
naviseccli -h <vnxa/vnxb> analyzer -get
naviseccli -h <vnxa/vnxb> analyzer -stop
naviseccli -h <vnxa/vnxb> analyzer -start
naviseccli -h <vnxa/vnxb> analyzer -archive -list
 
repeat on each SP as desired to confirm/make changes or retrieve files as needed.
 
 
 
Below is a sample output.  This shows that the Unisphere will work from either SPa or SPb and set the feature/options on both SPs.
 
 
C:\Users\schilt>naviseccli -h vnxa analyzer -status
Stopped on 02/03/2016 01:44:55
 
 
I then started the Data Logging from Unisphere and checked from cli:
 
 
C:\>naviseccli -h vnxa analyzer -status
Running. Started on 02/17/2016 00:18:28
 
C:\>naviseccli -h vnxb analyzer -status
Running. Started on 02/17/2016 00:18:28
 
 
C:\>naviseccli -h vnxa analyzer -get
Archive Poll Interval (sec):  60
Real Time Poll Interval (sec):  60
Periodic Archiving:  Yes
Current Logging Period (day):  1
 
 
C:\>naviseccli -h vnxb analyzer -get
Archive Poll Interval (sec):  60
Real Time Poll Interval (sec):  60
Periodic Archiving:  Yes
Current Logging Period (day):  1
 
Stop the analyzer from Unisphere and display the archive files from cli removing the excess files listed.
 
C:\>naviseccli -h vnxa analyzer -status
Stopped on 02/17/2016 00:46:04
 
C:\>naviseccli -h vnxb analyzer -status
Stopped on 02/17/2016 00:45:40
 
 
C:\>naviseccli -h vnxa analyzer -archive -list
Index Size in KB     Last Modified            Filename
0     87        09/19/2013 08:10:33  Serial-Number_SPA_2013-09-19_13-10-33-GMT_M06-00.nar
39    120       02/03/2016 00:44:54  Serial-Number_SPA_2016-02-03_06-44-54-GMT_M06-00.nar
40    94        02/16/2016 23:46:03  Serial-Number_SPA_2016-02-17_05-46-03-GMT_M06-00.nar
 
C:\Users\schilt>naviseccli -h vnxb analyzer -archive -list
Index Size in KB     Last Modified            Filename
0     90        09/19/2013 08:12:36  Serial-Number_SPB_2013-09-19_13-12-35-GMT_M06-00.nar
39    121       02/03/2016 00:44:55  Serial-Number_SPB_2016-02-03_06-44-54-GMT_M06-00.nar
40    95        02/16/2016 23:45:39  Serial-Number_SPB_2016-02-17_05-45-39-GMT_M06-00.nar