Dell EMC Unity: como fazer o upgrade do código de OE do Dell EMC Unity (corrigível pelo usuário).

Summary: Como fazer upgrade do código do OE do Unity

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Como fazer upgrade do código do OE do Unity

Método 1: Usando a GUI do Unisphere


1. Vá para o menu "settings" no Unisphere registrado como "admin or equivalent user"


kA5j00000008VQ7CAM_1_0
2. Navegue até "Software and Licenses > Software Upgrade"
kA5j00000008VQ7CAM_1_1
Nota:
Aqui, é mostrada a versão atual do Unity OE em que você está e também estas três opções
  • Realizar verificações de integridade
  • Iniciar upgrade
  • Faça download do novo software

3. Quando estiver pronto para iniciar o upgrade.
4. Opção "Perform Health Checks" antes de fazer upgrade
kA5j00000008VQ7CAM_1_2
Nota:
se houver avisos, trate-os primeiro antes de realizar o upgrade.

5. Carregue o arquivo de upgrade do OE do Unity baixado https://www.dell.com/support/home/ local.
kA5j00000008VQ7CAM_1_3
     

Como deve ficar Depois que o arquivo do Unity OE for carregado:
kA5j00000008VQ7CAM_1_4
Nota:
depois de pressionar o botão "Next", o sistema preparará o arquivo para o upgrade. Isso pode levar cerca de 5 a 10 minutos.

Nota: Se o upgrade for cancelado após essa etapa, verifique se a imagem foi excluída de /var/tmp/upgrade na controladora primária. Deixar o FS raiz em alto uso pode levar à pane da SP.

6. A próxima etapa é decidir quando reinicializar as controladoras de armazenamento. Se a opção for deixada selecionada, as controladoras de armazenamento serão reinicializadas, uma de cada vez, durante o upgrade. Se desmarcada, você mesmo pode reinicializar as SPs posteriormente (por meio de "Retomar upgrade"). O padrão é selecionar automaticamente para permitir que o Unity reinicialize as SPs conforme necessário.
kA5j00000008VQ7CAM_1_5

7. Analise a página de resumo e certifique-se de ver a versão anterior da nova Nota
kA5j00000008VQ7CAM_1_6
:

Leia a recomendação sobre quando fazer o upgrade.

8. Clique no botão "Finish" para iniciar o upgrade do Unity OE.
Se houver erros durante o upgrade, encaminhe as mensagens e os remédios para "Repetir". Se houver algum problema, entre em contato com o provedor de serviços. 
Durante o upgrade, o ambiente pode exibir erros ou alertas devido a reinicializações da SP, espaço insuficiente etc.

9. Após a conclusão do upgrade do OE do Unity, recarregue o Unisphere. O novo código agora deve ser exibido na "guia Summary" em "System View".

 

Method 2 : Using Command Line (uemcli)
1) Download the image first (We can use any clients that supports uemcli like windows, linux or even unity console itself. If Unity console is used, the image need to be copied to peer SP) Below is an example for a complete upgrade by uemcli.

 

a) SSH Login to the array using service account [Example: SPA is managing SP and SPB is peer SP ]
b) Get the upgrade image file using winSCP or sftp to /cores/service(Example: Unity-4.1.2.9257522.tgz.bin.gpg )
For OE 4.5+:
/cores/service/user/
c) Copy the image to peer SP : scp /cores/service/Unity-4.1.2.9257522.tgz.bin.gpg peer:/cores/service
For OE 4.5+:
scp /cores/service/user/Unity-4.1.2.9257522.tgz.bin.gpg peer:/cores/service/user
d) Delete the image from local SP (SPA in this example) : rm /cores/service/Unity-4.1.2.9257522.tgz.bin.gpg
For OE 4.5+:
rm /cores/service/user/Unity-4.1.2.9257522.tgz.bin.gpg
e) ssh to peer SP : ssh peer

 

 



2) Upload the image :
C:\> uemcli -d <unity_management_ip> -u admin -securePassword -upload -f c:\data\Unity-4.2.0.9392909.tgz.bin.gpg upgrade
Password:
Uploaded 2.01 GB of 2.01 GB [ 100%] -PROCESSING-
Operation Completed successfully

If the file was uploaded to Unity via SCP/SFTP:
uemcli -d <unity_management_ip> -u admin -securePassword -upload -f /cores/service/user/Unity-4.1.2.9257522.tgz.bin.gpg upgrade

Note: If the upgrade is cancelled after this step, make sure the image is deleted from /var/tmp/upgrade on the primary SP. Leaving the root FS in high usage could lead to SP panic.


3) Verify the image candidate ID
C:\> uemcli -d 10.0.0.1 -u admin -securePassword /sys/soft/ver show
Password:
1:    ID           = INST_1
      Type         = installed
      Version      = 4.1.1.9138882
      Release date = 2017-02-09 14:30:02

2:    ID           = CAND_1
      Type         = candidate
      Version      = 4.2.0.9392909
      Release date = 2017-06-28 11:28:31







4) Create (start) the upgrade (optional to specify pause before reboot, if not given full upgrade will start immediately):
C:\> uemcli -d 10.0.0.1 -u admin -securePassword /sys/soft/upgrade create -candId CAND_1 -pauseBeforeReboot

5) Monitor the upgrade :
C:\> uemcli -d 10.0.0.1 -u admin -securePassword /sys/soft/upgrade show -detail

6) Resume the upgrade if pause before reboot is given or any health checks failed (like Replication session not paused earlier) :
C:\> uemcli -d 10.0.0.1 -u admin -securePassword /sys/soft/upgrade resume

7) Verify after it completes

04:48:27 service@(none) spb:~> uemcli /sys/soft/ver show -detail

1:    ID              = INST_1
      Type            = installed
      Version         = 4.2.0.9392909
      Release date    = 2017-06-28 11:28:37
      Image type      =
      Reboot required =
      Pause allowed   =
      Image filename  =

04:48:36 service@(none) spb:~> uemcli /sys/soft/upgrade show -detail

1:    Status              = completed
      Creation time       = 2017-08-03 03:30:10
      Elapsed time        = 55m 36s
      Estimated time left =
      Progress            =
      Percent complete    = 100%

Additional Information

A DELL EMC recomenda realizar o upgrade do código OE do Unity durante um período de baixa produção. Não deve haver DU/DL durante o upgrade, mas pode deixar tudo mais lento e ter uma utilização mais alta da CPU durante o upgrade.

Antes do upgrade, os núcleos/serviços devem ter pelo menos 5 GB de espaço livre. Normalmente, excluir coletas de dados antigas é a melhor maneira de liberar esse espaço.

Se estiver fazendo upgrade para a versão 4.5 ou 4.5.1, consulte a KB
Dell EMC Unity: O repositório de dados de replicação não atualiza após o upgrade para a versão 4.5.0 ou 4.5.1 (corrigível pelo usuário) https://support.emc.com/kb/531543

Este artigo foi promovido como HVC na DECN (DECN) da DELL EMC: https://community.emc.com/docs/DOC-56665

Affected Products

Dell EMC Unity Family

Products

Dell EMC Unity Family
Article Properties
Article Number: 000022755
Article Type: How To
Last Modified: 01 Dec 2025
Version:  9
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.