ECS: xDoctor: RAP015: Blæserfejl

Summary: En blæser rapporterer en fejltilstand på noden.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

En blæser på noden er holdt op med at rapportere, at den fungerer.
En blæser har rapporteret, at den er i fejltilstand og kan forårsage overophedning af noden, hvis den ikke adresseres.  
----------------------
CRITICAL - Fan Failure
----------------------
Node      = 169.254.1.3
Extra     = {'node': '169.254.1.3', 'item': 'Fan1', 'status': 'CRIT', 'fan': 'System Board', 'info': '0 RPM, below critical threshold'}
RAP       = RAP015
Solution  = KB 470284
Timestamp = 2023-08-22_102927
PSNT      = CKMxxxxxxxxxxx @ 4.8-92.0
----------------------
CRITICAL - Fan Failure
----------------------
Node      = 169.254.1.3
Extra     = {'node': '169.254.1.3', 'item': 'Fan Redundancy', 'status': 'FAIL', 'fan': 'System Board', 'info': 'not redundant, redundancy lost'}
RAP       = RAP015
Solution  = KB 470284
Timestamp = 2023-08-22_102927
PSNT      = CKMxxxxxxxxxxx @ 4.8-92.0

Cause

Fejl i bevægelige komponenter på grund af elektrisk fejl eller alder.

Resolution

Opret forbindelse til den pågældende node, og bekræft problemet:
Bekræft blæserstatus på den rapporterede node ved hjælp af cs_hal.
 

Udsted, kommando: # cs_hal sensorer ventilator
 
Eksempel på en sund fan:
admin@node3:~> cs_hal sensors fan
Entity            Type                Label             Status  Info
-----             -----               -----             -----   -----
System Board      Fan                 Fan1              OK      12600 RPM
System Board      Fan                 Fan2              OK      12600 RPM
System Board      Fan                 Fan3              OK      16920 RPM
System Board      Fan                 Fan4              OK      16920 RPM
System Board      Fan                 Fan5              OK      17040 RPM
System Board      Fan                 Fan6              OK      17040 RPM
System Board      Fan                 Fan Redundancy    OK      fully redundant;

Nedenfor øges hastigheden på de andre blæsere, hvilket skaber mere luftgennemstrømning og holder noden kølig, indtil blæseren er blevet udskiftet.

Eksempel på en defekt blæser:

admin@node3:~> cs_hal sensors fan
Entity            Type                Label             Status  Info
-----             -----               -----             -----   -----
System Board      Fan                 Fan1              CRIT    0 RPM; below critical threshold
System Board      Fan                 Fan2              OK      13440 RPM
System Board      Fan                 Fan3              OK      20640 RPM
System Board      Fan                 Fan4              OK      20880 RPM
System Board      Fan                 Fan5              OK      20880 RPM
System Board      Fan                 Fan6              OK      20640 RPM
System Board      Fan                 Fan Redundancy    FAIL    not redundant; redundancy lost;
Udsted, kommando: # sudo ipmitool -H <BMC_IP> -U root -P passwd -I lanplus sdr type "Fan"
admin@node3:~> sudo ipmitool -H 192.168.219.103 -U root -P passwd -I lanplus sdr type "Fan"
Fan1             | 38h | lcr |  7.1 | 0 RPM     
Fan2             | 39h | ok  |  7.1 | 13440 RPM
Fan3             | 3Ah | ok  |  7.1 | 20640 RPM
Fan4             | 3Bh | ok  |  7.1 | 20880 RPM
Fan5             | 3Ch | ok  |  7.1 | 20880 RPM
Fan6             | 3Dh | ok  |  7.1 | 20640 RPM
Fan Redundancy   | 78h | ok  |  7.1 | Redundancy Lost
Udsted, kommando: # sudo -i racadm getsensorinfo
(cutting the complete output.)
admin@node3:~> sudo -i racadm getsensorinfo

Sensor Type : FAN
<Sensor Name>                   <Status>    <Reading>   <lc>        <uc>        <PWM %>     <Type>
System Board Fan1               Failed      0RPM        480RPM      NA          NA          High Performance 
System Board Fan2               Ok          13440RPM    480RPM      NA          65%         High Performance
System Board Fan3               Ok          20640RPM    480RPM      NA          100%        High Performance
System Board Fan4               Ok          20640RPM    480RPM      NA          100%        High Performance
System Board Fan5               Ok          20880RPM    480RPM      NA          100%        High Performance
System Board Fan6               Ok          20640RPM    480RPM      NA          100%        High Performance


<Sensor Name>                   <Status>                 <Type>
System Board PS Redundancy      Full Redundant           PSU
System Board Fan Redundancy     Redundancy Lost          Fan 

Hvis en ventilator har en status, der ikke er i orden med rapportering af CRIT, er blæseren defekt og skal udskiftes. Hvis du ikke har en serviceanmodning (SR) for dette problem, skal du åbne en med ECS-support, der henviser til denne KB.

Affected Products

ECS Appliance Hardware Gen1 U-Series

Products

ECS Appliance
Article Properties
Article Number: 000041145
Article Type: Solution
Last Modified: 30 Sep 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.