ECS: xDoctor: RAP015: Awaria wentylatora

Summary: Wentylator zgłasza stan awarii w węźle.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Wentylator węzła przestał zgłaszać, że urządzenie działa.
Wentylator zgłosił, że jest w stanie awarii i może spowodować przegrzanie węzła, jeśli nie zostanie rozwiązany.  
----------------------
CRITICAL - Fan Failure
----------------------
Node      = 169.254.1.3
Extra     = {'node': '169.254.1.3', 'item': 'Fan1', 'status': 'CRIT', 'fan': 'System Board', 'info': '0 RPM, below critical threshold'}
RAP       = RAP015
Solution  = KB 470284
Timestamp = 2023-08-22_102927
PSNT      = CKMxxxxxxxxxxx @ 4.8-92.0
----------------------
CRITICAL - Fan Failure
----------------------
Node      = 169.254.1.3
Extra     = {'node': '169.254.1.3', 'item': 'Fan Redundancy', 'status': 'FAIL', 'fan': 'System Board', 'info': 'not redundant, redundancy lost'}
RAP       = RAP015
Solution  = KB 470284
Timestamp = 2023-08-22_102927
PSNT      = CKMxxxxxxxxxxx @ 4.8-92.0

Cause

Awaria ruchomego elementu spowodowana awarią elektryczną lub wiekiem.

Resolution

Połącz się z danym węzłem i sprawdź problem:
sprawdź stan wentylatora w zgłoszonym węźle za pomocą cs_hal.
 

Polecenie: # cs_hal wentylator czujników
 
Przykład sprawnego wentylatora:
admin@node3:~> cs_hal sensors fan
Entity            Type                Label             Status  Info
-----             -----               -----             -----   -----
System Board      Fan                 Fan1              OK      12600 RPM
System Board      Fan                 Fan2              OK      12600 RPM
System Board      Fan                 Fan3              OK      16920 RPM
System Board      Fan                 Fan4              OK      16920 RPM
System Board      Fan                 Fan5              OK      17040 RPM
System Board      Fan                 Fan6              OK      17040 RPM
System Board      Fan                 Fan Redundancy    OK      fully redundant;

Jak pokazano poniżej, prędkość innych wentylatorów wzrasta, tworząc większy przepływ powietrza, aby utrzymać chłodzenie węzła do czasu wymiany wentylatora.

Przykład uszkodzonego wentylatora:

admin@node3:~> cs_hal sensors fan
Entity            Type                Label             Status  Info
-----             -----               -----             -----   -----
System Board      Fan                 Fan1              CRIT    0 RPM; below critical threshold
System Board      Fan                 Fan2              OK      13440 RPM
System Board      Fan                 Fan3              OK      20640 RPM
System Board      Fan                 Fan4              OK      20880 RPM
System Board      Fan                 Fan5              OK      20880 RPM
System Board      Fan                 Fan6              OK      20640 RPM
System Board      Fan                 Fan Redundancy    FAIL    not redundant; redundancy lost;
Polecenie: # sudo ipmitool -H <BMC_IP> -U root -P passwd -I lanplus sdr wpisz "Fan"
admin@node3:~> sudo ipmitool -H 192.168.219.103 -U root -P passwd -I lanplus sdr type "Fan"
Fan1             | 38h | lcr |  7.1 | 0 RPM     
Fan2             | 39h | ok  |  7.1 | 13440 RPM
Fan3             | 3Ah | ok  |  7.1 | 20640 RPM
Fan4             | 3Bh | ok  |  7.1 | 20880 RPM
Fan5             | 3Ch | ok  |  7.1 | 20880 RPM
Fan6             | 3Dh | ok  |  7.1 | 20640 RPM
Fan Redundancy   | 78h | ok  |  7.1 | Redundancy Lost
Polecenie: # sudo -i racadm getsensorinfo
(cutting the complete output.)
admin@node3:~> sudo -i racadm getsensorinfo

Sensor Type : FAN
<Sensor Name>                   <Status>    <Reading>   <lc>        <uc>        <PWM %>     <Type>
System Board Fan1               Failed      0RPM        480RPM      NA          NA          High Performance 
System Board Fan2               Ok          13440RPM    480RPM      NA          65%         High Performance
System Board Fan3               Ok          20640RPM    480RPM      NA          100%        High Performance
System Board Fan4               Ok          20640RPM    480RPM      NA          100%        High Performance
System Board Fan5               Ok          20880RPM    480RPM      NA          100%        High Performance
System Board Fan6               Ok          20640RPM    480RPM      NA          100%        High Performance


<Sensor Name>                   <Status>                 <Type>
System Board PS Redundancy      Full Redundant           PSU
System Board Fan Redundancy     Redundancy Lost          Fan 

Jeśli jakikolwiek wentylator ma stan, który nie zgadza się ze zgłaszaniem krytycznych trafień, oznacza to, że wentylator uległ awarii i należy go wymienić. Jeśli nie masz zgłoszenia serwisowego (SR) dotyczącego tego problemu, otwórz zgłoszenie z pomocą techniczną ECS, odwołując się do tego artykułu bazy wiedzy.

Affected Products

ECS Appliance Hardware Gen1 U-Series

Products

ECS Appliance
Article Properties
Article Number: 000041145
Article Type: Solution
Last Modified: 30 Sep 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.