Avamar Gen4S 硬體:瞭解週期逾時

Summary: Avamar Gen4S 硬體上的學習週期失敗。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Avamar UI 或記錄中出現下列錯誤:

<MRMON154> Controller ID: 0 Battery relearn timed out 

Cause

供應商正在檢閱此項目。

Resolution

1.以系統管理員身分登入 Avamar 伺服器,提升至 root,然後載入 SSH 鍵來向下捲動頁面。

如需有關載入金鑰的指示,請參閱 Avamar:如何登入 Avamar Server 並載入各種金鑰。

2.使用 UI 事件或 Dial Home 服務要求中的資訊:

一個。確定產生錯誤消息的節點。

b.以 root 身分連線至該節點:

ssn 0.# --user=root

(其中 0.# 為實體節點編號)

3.解壓縮 /var/log/messages 使用下列適用命令的檔案:

bunzip2 /var/log/messages*
gunzip /var/log/messages*
xz --decompress /var/log/messages*
 

4.檢閱電池重新學習 事件的消息記錄 (/var/log/messages):

grep -i "battery relearn" /var/log/messages
Jul 29 13:37:12 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON157> Controller ID:  0   Battery relearn will start in 4 days Jul 31 13:37:48 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON158> Controller ID:  0   Battery relearn will start in 2 days Aug  1 13:37:33 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON159> Controller ID:  0   Battery relearn will start in 1 day Aug  2 08:37:13 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON160> Controller ID:  0   Battery relearn will start in 5 hours Aug  2 13:38:24 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON155> Controller ID:  0   Battery relearn pending: Battery is under     charge Aug  2 13:39:28 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON151> Controller ID:  0   Battery relearn started Aug  2 13:40:36 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON152> Controller ID:  0   Battery relearn in progress Aug  2 13:40:36 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON153> Controller ID:  0   Battery relearn completed Aug 13 16:32:15 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON155> Controller ID:  0   Battery relearn pending: Battery is under     charge Aug 13 16:44:10 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON151> Controller ID:  0   Battery relearn started Aug 13 16:45:15 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON152> Controller ID:  0   Battery relearn in progress Aug 13 16:48:30 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON154> Controller ID:  0   Battery relearn timed out 
 

5.確認使用 CmdTool2 學習失敗,但電池未顯示 0 伏特:

CmdTool2 -AdpBbuCmd -GetBbuStatus -a0 
BBU status for Adapter: 0

BatteryType: CVPM02
Voltage: 9563 mV
Current: 0 mA
Temperature: 30 C

BBU Firmware Status:

  Charging Status              : None
  Voltage                                 : OK
  Temperature                             : OK
  Learn Cycle Requested                   : No
  Learn Cycle Active                      : No
  Learn Cycle Status                      : Failed
  Learn Cycle Timeout                     : Yes
  I2c Errors Detected                     : No
  Battery Pack Missing                    : No
  Battery Replacementrequired             : No
  Remaining CapacityLow                   : No
  Periodic Learn Required                 : No
  Transparent Learn                       : No
  No space to cache offload               : No
  Pack is about to fail & should be replaced : No
  Cache Offload premium feature required  : No
  Module microcode update required        : No 

GasGuageStatus:
  Fully Discharged        : No
  FullyCharged            : Yes
  Discharging             : Yes
  Initialized             : No
  Remaining Time Alarm    : No
  Remaining Capacity Alarm: No
  Discharge Terminated    : No
  OverTemperature         : No
  Charging Terminated     : Yes
  Over Charged            : No

  Pack energy             : 96 J
  Capacitance             : 100
  Remaining reserve space : 93 

Exit Code: 0x00
 

6.啟動手動學習週期:

sudo CmdTool2 -AdpBbuCmd -BbuLearn -a0
 

7.檢閱訊息記錄,看看記憶週期是否開始和結束。

範例 1:

Aug  26 12:15:01 AVAMAR-GRID-VAR-LOG-MESSAGE syslog-ng[3170]: Configuration reload request received, reloading configuration;
Aug  26 12:15:01 AVAMAR-GRID-VAR-LOG-MESSAGE syslog-ng[3170]: New configuration initialized;
Aug  26 12:15:11 AVAMAR-GRID-VAR-LOG-MESSAGE sudo:    admin : TTY=pts/0 ; PWD=/data01/home/admin ; USER=root ; COMMAND=/opt/MegaRAID/CmdTool2/CmdTool2 -pdlist -a0 -nolog
Aug  26 12:16:10 AVAMAR-GRID-VAR-LOG-MESSAGE sudo:    admin : TTY=pts/0 ; PWD=/data01/home/admin ; USER=root ; COMMAND=/opt/MegaRAID/CmdTool2/CmdTool2 -AdpBbuCmd -GetBbuStatus -a0
Aug  26 12:18:28 AVAMAR-GRID-VAR-LOG-MESSAGE sudo:    admin : TTY=pts/0 ; PWD=/data01/home/admin ; USER=root ; COMMAND=/opt/MegaRAID/CmdTool2/CmdTool2 -AdpBbuCmd -BbuLearn -a0
Aug  26 12:18:31 AVAMAR-GRID-VAR-LOG-MESSAGE MR_MONITOR[5742]:  Controller ID:  0   Battery relearn pending: Battery is under     charge
Aug  26 12:19:36 AVAMAR-GRID-VAR-LOG-MESSAGE MR_MONITOR[5742]:  Controller ID:  0   Battery relearn started
Aug  26 12:20:02 AVAMAR-GRID-VAR-LOG-MESSAGE sudo:    admin : TTY=pts/0 ; PWD=/data01/home/admin ; USER=root ; COMMAND=/opt/MegaRAID/CmdTool2/CmdTool2 -AdpBbuCmd -GetBbuStatus -a0
Aug  26 12:20:44 AVAMAR-GRID-VAR-LOG-MESSAGE MR_MONITOR[5742]:  Controller ID:  0   Battery relearn in progress
Aug  26 12:20:44 AVAMAR-GRID-VAR-LOG-MESSAGE MR_MONITOR[5742]:  Controller ID:  0   Battery relearn completed
Aug  26 12:22:25 AVAMAR-GRID-VAR-LOG-MESSAGE sudo:    admin : TTY=pts/0 ; PWD=/data01/home/admin ; USER=root ; COMMAND=/opt/MegaRAID/CmdTool2/CmdTool2 -AdpBbuCmd -GetBbuStatus -a0

雖然重新學習似乎已完成,但完成的時間卻很短 (這並不正常)。

範例 2:

Aug 26 01:30:23 AVATPCKVS41N05 sudo:     root : TTY=pts/0 ; PWD=/root ; USER=root ; COMMAND=/opt/MegaRAID/CmdTool2/CmdTool2 -AdpBbuCmd -BbuLearn -a0
Aug 26 01:31:12 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON155> Controller ID:  0   Battery relearn pending: Battery is under     charge
Aug 26 16:44:10 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON151> Controller ID:  0   Battery relearn started
Aug 26 16:45:15 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON152> Controller ID:  0   Battery relearn in progress
Aug 26 16:48:30 AVATPCKVS41N05 MR_MONITOR[8625]: <MRMON154> Controller ID:  0   Battery relearn timed out

在這裡,「重新學習」超時了。

8.重新檢查電池狀態:

CmdTool2 -AdpBbuCmd -GetBbuStatus -a0
 

如果狀態為正常且沒有逾時 (如下所示),則不需要採取進一步動作。

BBU status for Adapter: 0

BatteryType: CVPM02
Voltage: 9563 mV
Current: 0 mA
Temperature: 30 C

BBU Firmware Status:

  Charging Status              : None
  Voltage                                 : OK
  Temperature                             : OK
  Learn Cycle Requested                   : No
  Learn Cycle Active                      : No
  Learn Cycle Status                      : OK
  Learn Cycle Timeout                     : No
  I2c Errors Detected                     : No
...
 

 如果問題仍如下所示,請建立提供上述輸出的服務要求,以判斷是否需要更換節點。

BBU status for Adapter: 0

BatteryType: CVPM02
Voltage: 9563 mV
Current: 0 mA
Temperature: 30 C

BBU Firmware Status:

  Charging Status              : None
  Voltage                                 : OK
  Temperature                             : OK
  Learn Cycle Requested                   : No
  Learn Cycle Active                      : No
  Learn Cycle Status                      : Failed
  Learn Cycle Timeout                     : Yes
  I2c Errors Detected                     : No
  ...

Affected Products

Avamar, Avamar Server
Article Properties