ECS: Odkaz na postup NFSv3 není podporován v požadavku ReadLinkRequest
Summary: Chyba streamování protokolu funkce dataheadsvc: Odkaz na postup NFSv3 není podporován v požadavku ReadLinkRequest.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Protokol dataheadsvc streamuje následující chyby:
Command:# cat /opt/emc/caspian/fabric/agent/services/object/main/log/dataheadsvc.log
Příklad:
2018-08-16T10:13:35,312 [RpcDispatcherMD-1392] INFO COMMIT3Handler.java (line 132) Retrieved attributes for : 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240 Size : 1010564 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] WARN RpcProgramNfs3.java (line 239) **************** NFSv3 procedure LINK not supported in request ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 169) Response : Rpc error : Nfsv3 procedure LINK not supported in ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1391] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1441996478 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = b2fac0d51058bc3138b4da067ed3ca5eb7781e3cd95a9ac535ea3664c7b71f62, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,314 [RpcDispatcherMD-1284] ERROR RpcProgramNfs3.java (line 294) Error processing NfsRequest: xid:1458773694 ip:/10.1.1.78 SysSecurity: AuthStatus:AUTH_OK Uid:1001 Gid:1001 Proc:LINK ReadLinkRequest : FileHandle:[objectId = 3e53eabbb55102dffba9e462c55656dedaf10f7b9f4389d322173f3ecd295240, ownerZoneUUID = ecb84411-2609-4467-b6ea-14d0f851ccc4]Export:1 NfsResponse: null RpcError: PROC_UNAVAIL 2018-08-16T10:13:35,317 [RpcDispatcherMD-1356-0a01821f:165323f0b49:ef:2838a52] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD 2018-08-16T10:13:35,318 [RpcDispatcherMD-1298-0a01821f:165323f0b49:e6:283489e] WARN FileSystemAccessHelper.java (line 1931) nfsProcessOperation : Object objectId : was not found by method nfsGetSMD
Cause
Postup systému souborů NFS (Network File System) používaný klientskou operací je LINK, což je pevný odkaz. Tato možnost není podporována.
Resolution
NFS podporuje všechny postupy NFSv3 KROMĚ LINK: Vytvořte pevný odkaz na objekt.
Additional Information
Viz část NFS v technických častých dotazech.
Affected Products
Elastic Cloud StorageProducts
Elastic Cloud StorageArticle Properties
Article Number: 000042857
Article Type: Solution
Last Modified: 12 Sep 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.