VNX: USM Install DAE fails with error message (User Correctable)
Summary: USM DAE add fails with error. "A fault has been detected on the storage system. Contact your service provider immediately for assistance. Installation cannot continue while the storage system is in this state." ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
In Unisphere Service Manager (USM), when trying to add a DAE ( Hardware--> Hardware Installation--> Install Disk Array Enclosure), the page with the bus selection does not appear and after clicking next, in the page where the cables should be connected, the DAE add is failing with error message:
"A fault has been detected on the storage system. Contact your service provider immediately for assistance. Installation cannot continue while the storage system is in this state."
This only happens in case one bus has already got the maximum number of DAEs.

Cause
When USM's DAE Installation Wizard encountered a bus full of enclosures, it ignored any remaining buses, preventing USM from displaying the proper enclosures.
Resolution
Install the latest USM version 1.3.9.1.0236-1.
Affected Products
VNX2 SeriesProducts
VNX2 SeriesArticle Properties
Article Number: 000050533
Article Type: Solution
Last Modified: 11 Oct 2024