VNX: Unisphere HTTP Error 403: Forbidden - Create Replication Session (User Correctable)

Summary: Unable to create a replication session using Unisphere

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



Getting the following error while trying to create a replication session using Unisphere: 

HTTP Error 403: Forbidden 
                1) Check if the Data Movers on the specified remote system are accessible. 
                2) Ensure that the difference in system times between the local and remote VNX File systems or VNX systems does not exceed 10 minutes. 
                Use NTP on the Control Stations to synchronize the system clocks. 
                3) Ensure that the passphrase on the local Control Station matches with the passphrase on the remote Control Station.
                4) Ensure that the same local users that manage VNX for file systems exist on both the source and the destination Control Station. 
                5) Ensure that the global account is mapped to the same local account on both local and remote VNX Control Stations. Primus emc263860 provides more details. 
                
                Message ID: 13690601568   

MessageID = 13690601568
BaseID    = 96
Severity  = ERROR
Component = APL
Facility  = common
Type      = STATUS

Brief_Description  = Cannot access any Data Mover on the remote system, ${remotesystem,8,%s}

Full_Description   = No Data Movers are available on the specified remote system to perform this operation

Recommended_Action = 1) Check if the Data Movers on the specified remote system are accessible. 2) Ensure that the difference in system times between the local and remote Celerra systems or VNX systems does not exceed 10 minutes. Use NTP on the Control Stations to synchronize the system clocks. 3) Ensure that the passphrase on the local Control Station matches with the passphrase on the remote Control Station. 4) Ensure that the same local users that manage VNX for file systems exist on both the source and the destination Control Station. 5) Ensure that the global account is mapped to the same local account on both local and remote VNX Control Stations. Primus emc263860 provides more details.

Cause

Source and Destination Control stations time and/or timezone does not match. NTP was not configured to sync the time between the Source and the Destination array.

Resolution

Ideally, the time difference between the source and destination array should not be more than 10 minutes, and it should reflect same in both Unisphere as well as in the PuTTY session.
  1. Check the timezone for both source and destination array in Unisphere (It should be same)
  2. Check nas_cs -i (It was different for Source and destination, so as getting the error)

How to change the CS Time:  

Follow these steps to set the Control Station date and time:  
  1. Log in to Unisphere as root.
  2. Select the System from the drop down list.
  3. From the System Management task list, select Control Station Properties.
  4. In the Current Date and Time field, select the Month, Day, and Year from the corresponding lists.
  5. In the Time field, type the time of day in hh:mm:ss format.
  6. From the Current Timezone list, select the timezone.
  7. Click Apply.
CLI:  
nas_cs  set  time <yymmddhhmm>  timezone
<timezone>


nas_cs  set  time 200811070205  timezone
America/New_York

After the update of time, replication session will be created successfully.

Additional Information

The above steps are only applicable when NTP is not configured for the arrays.

In order to configure the NTP for the array, refer to KB article 322783, Celerra and VNX: How to configure NTP for the Data Mover and Control Station.

Reference: 
  • Display the current date and time
/nas/httpnas/http/webui/bin/datetime.pl -s 2011-03-02T11:19:00
 
  • Confirm the date and time are correct:
nas/http/webui/bin/datetime.pl -g

For example: 
2011-03-02T11:19:02

List the time zones supported by the Control Station:
 
nas/http/webui/bin/timezone.pl -l | sed 's/,/\n/g'| more

GMT-12
GMT-11
GMT-10
GMT-9
GMT-8
.........
.........

nas/http/webui/bin/timezone.pl -l | sed 's/,/\n/g' | grep Australia

Australia/Adelaide
Australia/Brisbane
Australia/Broken_Hill
Australia/Currie
Australia/Darwin
Australia/Eucla
Australia/Hobart
Australia/Lindeman
Australia/Lord_Howe
Australia/Melbourne
Australia/Perth
Australia/Sydney

Products

VNX1 Series, VNX2 Series, VNX/VNXe
Article Properties
Article Number: 000052324
Article Type: Solution
Last Modified: 07 Nov 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.