NVP-vProxy:备份失败并“故障恢复到以前的备份模式”

Summary: NetWorker VMware Protection (NVP) 虚拟机 (VM) 备份失败。报告的错误是备份故障恢复到以前的备份模式。更改策略组中的备份优化模式后,会出现此错误。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

VMware 保护组的备份优化模式已更改。

NetWorker VMware 保护集成配置了 vProxy Appliance。VMware 保护组的备份失败,表明备份模式与虚拟机 (VM) 不匹配。备份作详细信息和日志显示:
MM/DD/YYYY HH:mm:SS [VM_NAME]: Perform incremental backup.
MM/DD/YYYY HH:mm:SS [VM_NAME]: Falling back to the previous backup mode 'VSS'. The configured backup mode 'FSS_8K' does not match the previous mode. Run a full backup to switch the backup mode.
MM/DD/YYYY HH:mm:SS [VM_NAME]: Started backup with job ID '571746' for save-set ID 'e0deff0f-00000006-3f7c58db-5b7c58db-dcc20000-22cafcc9' on vProxy '[VPROXY_NAME]'.
MM/DD/YYYY HH:mm:SS [VM_NAME]: Downloaded vProxy Session log file '/nsr/logs/policy/[POLICY_NAME]/[WORKFLOW_NAME]/571746-[VM_NAME]-YYYY-MM-DD-HH-MM-SS.log' under savejob 571746.
MM/DD/YYYY HH:mm:SS [VM_NAME]: Backup failed.

Cause

在执行初始完整零级备份后,VMware 保护组的备份优化模式已更改。切换虚拟机的备份优化模式需要新的完整(零级)备份,作为未来备份的基准。

Resolution

更改备份作配置,以强制执行新优化模式的完整级别备份。完整级别备份完成后,可以将备份作配置更改回增量备份。

Additional Information

确保 Data Domain 设备具有足够的容量。在转换期间,两种备份模式共存,使存储使用量翻倍,直到最后一个针对容量进行了优化备份根据其保留期到期。在此之后,存储消耗将恢复正常。

有关详细信息,请参阅 NetWorker VMware 集成指南的“vProxy 备份优化模式”部分: https://www.dell.com/support/product-details/product/networker/docs

Affected Products

NetWorker

Products

NetWorker Family
Article Properties
Article Number: 000052960
Article Type: Solution
Last Modified: 14 Aug 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.