luxadm display fails with "Error: Invalid pathname " for VMAX-250F devices
Summary: luxadm display fails with "Error: Invalid pathname " for VMAX-250F devices
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Environment : Solaris 10 u11 guest domain on SR-IOV
luxadm display fails with "Error: Invalid pathname " for VMAX-250F devices
bash-3.2# luxadm display /dev/rdsk/c3t6000097000000000000000033030303437d0s2
DEVICE PROPERTIES for disk: /dev/rdsk/c3t6000097000000000000000033030303437d0s2
Vendor: EMC
Product ID: SYMMETRIX
Revision: 5977
Serial Num: 000000000000
Unformatted capacity: 10241.250 MBytes
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0xffff
Device Type: Disk device
Path(s):
/dev/rdsk/c3t6000097000000000000000033030303437d0s2
/devices/scsi_vhci/ssd@g6000097000000000000000033030303437:c,raw
Controller /devices/pci@300/pci@1/pci@0/pci@11/SUNW,qlc@0,2/fp@0,0
Device Address 5000000000000098,2
Error: Invalid pathname - /devices/pci@300/pci@1/pci@0/pci@11/SUNW,qlc@0,2/fp@0,0.
Cause
This is an Oracle Solaris Bug known as Bug 20533804
Resolution
Upgrade the gust domain to Solaris 11.2 or higher, or change from SR-IOV to V-IO.
Affected Products
PowerPath for SolarisProducts
PowerPath for SolarisArticle Properties
Article Number: 000056285
Article Type: Solution
Last Modified: 17 Oct 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.