VNX: Hændelseskode: 0xfffffffffffffff9 ; Fejl HC_BE_14505017506 Følgende domænefil(er) findes ikke

Summary: Unisphere giver 0xfffffffffffffff9 advarsel, når du logger på, eller Filindstillinger er deaktiveret i Unisphere.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Control Station failover/failback

  1. Filindstillinger er deaktiveret i Unisphere

  2. Loginadvarsel eller -fejl

    Message :            Logging into 172.28.7.60 encountered an error.
    Full Description :               An error occurred during the login process. The control station did not log in properly.
    Recommended Action :   The login error may have occurred because:
    1. Certificates are not accepted.
    2. Both storage processors or the control station are not accessible.
    3. You have logged in to a File or Block system using a local user account not defined on both the File and Block systems.
    Event Code :       0xfffffffffffffff9
  3. nas_checkup fejl:

    -------------------------------------Errors-------------------------------------
    Storage System : Check for domain and federations health on VNX
    Error HC_BE_14505017506: The following domain file(s) does not exist
              * /nas/http/domain/domain_list
              * /nas/http/domain/domain_master
              * /nas/http/domain/domain_provider_xml
    Action : Contact your service provider and reference EMC Knowledgebase
             article emc273714.

 

Cause

I de mest observerede tilfælde forårsager Control Station-failover eller genstart, at domænefilerne bliver beskadiget.

 

Resolution

Hvis kontrolstationen mislykkes over til slot_1, skal du failback kontrolstationen ved at logge ind slot_1 Control Station og genstarte den.

Hvis du har adgang til Putty-session (ssh) til Control Station (Primary), kan du prøve kommandoen (Skriv "yes", når du bliver bedt om det):

[nasadmin@VNX137 ~]$ /nasmcd/sbin/getreason

Hvis resultatet viser, at:

slot_1 Primary Control station
slot_0 Secondary Control station

Du skal svigte kontrolstationen ved at genstarte den slot_1 kontrolstation. Log på som root (su), og kør følgende kommando:

[nasadmin@VNX137 ~]# reboot

Dette ville tage et par minutter at genstarte kontrolstationen, og den kommer op i den oprindelige konfiguration.

Når kontrolstationerne er tilbage på oprindelig status, skal du kontrollere domænefilerne:

[nasadmin@VNX137 ~]$ /nasmcd/sbin/getreason
10 - slot_0 primary control station
11 - slot_1 secondary control station
5 - slot_4 contacted
5 - slot_3 contacted

[nasadmin@VNX137 ~]$ ll /nas/http/domain
total 15
drwxr-xr-x 2 apache apache 1024 Jun 27 14:35 bak
drwxr-xr-x 2 apache apache 1024 Nov 14  2013 ldap
-rw-r--r-- 1 apache apache    0 Mar 24 22:04 lock_file
[nasadmin@VNX137 ~]$

Kontroller, at Control Station-værtsnavnet er det samme som i lagerdomænet:

[nasadmin@VNX137 ~]$ hostname
VNX137
[nasadmin@VNX137 ~]$ hostname -i
10.31.139.137
[nasadmin@VNX137 ~]$ grep initiator /nas/dos/slot_3/boot.cfg
setinitiator cs_hostname=Celerra_VNX137 cs_external_ip=10.31.139.137

[nasadmin@VNX137 ~]$ /nas/sbin/navicli -h spa domain -list
Node:                 VNX_137
IP Address:           10.31.139.141 (Master)
Name:                 SPA
Port:                 80
Secure Port:          443
IP Address:           10.31.139.142
Name:                 SPB
Port:                 80
Secure Port:          443
IP Address:           10.31.139.137
Name:                 Celerra_VNX137
Port:                 80
Secure Port:          443

[nasadmin@VNX137 ~]$

Hvis den eksterne IP for den primære kontrolstation ikke stemmer overens, skal du følge scenarie 3 i artiklen https://support.emc.com/kb/448653 ellers gå videre.

Som root run under kommandoer:
# /nas/http/webui/bin/domain_admin -i <CS_IP>
# /nas/sbin/naviseccli -h SPA -user sysadmin -password sysadmin -scope 0 domain -messner -add -system <CS_IP>
# /nas/http/webui/bin/update_domain_directory.pl

Kontroller derefter de opdaterede domænefiler:

[nasadmin@VNX137 ~]$ ll /nas/http/domain
total 13
drwxr-xr-x 2 apache apache 1024 Sep  1 10:20 bak
-rw-r--r-- 1 apache apache   64 Sep  8 12:00 domain_list
-rw-r--r-- 1 apache apache  194 Sep  8 12:00 domain_master
-rw-r--r-- 1 apache apache 6764 Sep  8 12:00 domain_provider_xml
-rw------- 1 apache apache   58 Sep  8 12:00 domain_users
-rw-r--r-- 1 apache apache   47 Sep  1 10:20 domain_version
drwxr-xr-x 2 apache apache 1024 Nov 14  2013 ldap
-rw-r--r-- 1 apache apache    0 Aug 23 14:46 lock_file

Log nu på Unisphere for at kontrollere, om advarslen er ryddet, og filindstillingerne er oppe.

 

Affected Products

VNX/VNXe

Products

VNX1 Series, VNX2 Series, VNX5300, VNX5400, VNX5500, VNX5600, VNX5700, VNX5800, VNX7500, VNX7600, VNX8000, VNX/VNXe
Article Properties
Article Number: 000056520
Article Type: Solution
Last Modified: 18 Nov 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.