VNX: Codice evento: 0xfffffffffffffff9 ; Errore HC_BE_14505017506 I seguenti file di dominio non esistono

Summary: Unisphere visualizza 0xfffffffffffffff9 avviso durante l'accesso o le opzioni File sono disabilitate in Unisphere.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Failover/failback della control station

  1. Le opzioni file sono disabilitate in Unisphere

  2. Avviso o errore di accesso

    Message :            Logging into 172.28.7.60 encountered an error.
    Full Description :               An error occurred during the login process. The control station did not log in properly.
    Recommended Action :   The login error may have occurred because:
    1. Certificates are not accepted.
    2. Both storage processors or the control station are not accessible.
    3. You have logged in to a File or Block system using a local user account not defined on both the File and Block systems.
    Event Code :       0xfffffffffffffff9
  3. nas_checkup errore:

    -------------------------------------Errors-------------------------------------
    Storage System : Check for domain and federations health on VNX
    Error HC_BE_14505017506: The following domain file(s) does not exist
              * /nas/http/domain/domain_list
              * /nas/http/domain/domain_master
              * /nas/http/domain/domain_provider_xml
    Action : Contact your service provider and reference EMC Knowledgebase
             article emc273714.

 

Cause

Nei casi più frequenti, il failover o il riavvio di Control Station causano il danneggiamento dei file di dominio.

 

Resolution

Se viene eseguito il failover della control station su slot_1, eseguire il failback della control station accedendo a slot_1 control station e riavviandola.

Se si ha accesso alla sessione PuTTY (ssh) per Control Station (primaria), provare il comando (digitare "yes" quando richiesto):

[nasadmin@VNX137 ~]$ /nasmcd/sbin/getreason

Se il risultato mostra che:

slot_1 Primary Control station
slot_0 Secondary Control station

È necessario eseguire il failback della control station riavviando la control station slot_1. Accedere come root (su) ed eseguire il seguente comando:

[nasadmin@VNX137 ~]# reboot

L'operazione richiede alcuni minuti per riavviare la control station e ripristinare la configurazione originale.

Una volta ripristinati lo stato originale delle control station, controllare i file di dominio:

[nasadmin@VNX137 ~]$ /nasmcd/sbin/getreason
10 - slot_0 primary control station
11 - slot_1 secondary control station
5 - slot_4 contacted
5 - slot_3 contacted

[nasadmin@VNX137 ~]$ ll /nas/http/domain
total 15
drwxr-xr-x 2 apache apache 1024 Jun 27 14:35 bak
drwxr-xr-x 2 apache apache 1024 Nov 14  2013 ldap
-rw-r--r-- 1 apache apache    0 Mar 24 22:04 lock_file
[nasadmin@VNX137 ~]$

Verificare che il nome host della Control Station sia uguale a quello del dominio di storage:

[nasadmin@VNX137 ~]$ hostname
VNX137
[nasadmin@VNX137 ~]$ hostname -i
10.31.139.137
[nasadmin@VNX137 ~]$ grep initiator /nas/dos/slot_3/boot.cfg
setinitiator cs_hostname=Celerra_VNX137 cs_external_ip=10.31.139.137

[nasadmin@VNX137 ~]$ /nas/sbin/navicli -h spa domain -list
Node:                 VNX_137
IP Address:           10.31.139.141 (Master)
Name:                 SPA
Port:                 80
Secure Port:          443
IP Address:           10.31.139.142
Name:                 SPB
Port:                 80
Secure Port:          443
IP Address:           10.31.139.137
Name:                 Celerra_VNX137
Port:                 80
Secure Port:          443

[nasadmin@VNX137 ~]$

Se l'IP esterno della control station primaria non corrisponde, seguire lo scenario 3 nell'articolo https://support.emc.com/kb/448653 in caso contrario andare oltre.

Come utente root, eseguire i comandi riportati di seguito:
# /nas/http/webui/bin/domain_admin -i <CS_IP>
# /nas/sbin/naviseccli -h SPA -user sysadmin -password sysadmin -scope 0 domain -messner -add -system <CS_IP>
# /nas/http/webui/bin/update_domain_directory.pl

Quindi verificare i file di dominio aggiornati:

[nasadmin@VNX137 ~]$ ll /nas/http/domain
total 13
drwxr-xr-x 2 apache apache 1024 Sep  1 10:20 bak
-rw-r--r-- 1 apache apache   64 Sep  8 12:00 domain_list
-rw-r--r-- 1 apache apache  194 Sep  8 12:00 domain_master
-rw-r--r-- 1 apache apache 6764 Sep  8 12:00 domain_provider_xml
-rw------- 1 apache apache   58 Sep  8 12:00 domain_users
-rw-r--r-- 1 apache apache   47 Sep  1 10:20 domain_version
drwxr-xr-x 2 apache apache 1024 Nov 14  2013 ldap
-rw-r--r-- 1 apache apache    0 Aug 23 14:46 lock_file

A questo punto, accedere a Unisphere per verificare se l'avviso è stato cancellato e le opzioni File sono attive.

 

Affected Products

VNX/VNXe

Products

VNX1 Series, VNX2 Series, VNX5300, VNX5400, VNX5500, VNX5600, VNX5700, VNX5800, VNX7500, VNX7600, VNX8000, VNX/VNXe
Article Properties
Article Number: 000056520
Article Type: Solution
Last Modified: 18 Nov 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.