VNX:事件代碼:0xfffffffffffffff9 ;錯誤HC_BE_14505017506以下域檔不存在
Summary: Unisphere 在登入或 Unisphere 中的「檔案」選項停用時發出警告0xfffffffffffffff9。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
控制站容錯移轉/故障復原
-
Unisphere 中已停用「檔案選項」
-
登入警告或錯誤
Message : Logging into 172.28.7.60 encountered an error. Full Description : An error occurred during the login process. The control station did not log in properly. Recommended Action : The login error may have occurred because: 1. Certificates are not accepted. 2. Both storage processors or the control station are not accessible. 3. You have logged in to a File or Block system using a local user account not defined on both the File and Block systems. Event Code : 0xfffffffffffffff9
-
nas_checkup錯誤:
-------------------------------------Errors------------------------------------- Storage System : Check for domain and federations health on VNX Error HC_BE_14505017506: The following domain file(s) does not exist * /nas/http/domain/domain_list * /nas/http/domain/domain_master * /nas/http/domain/domain_provider_xml Action : Contact your service provider and reference EMC Knowledgebase article emc273714.
Cause
在最常見的情況下,控制站容錯移轉或重新開機會導致網域檔案損毀。
Resolution
如果控制站已故障轉移到 slot_1,則通過登入控制站並重新啟動slot_1對控制站進行故障復原。
如果您有權存取 Putty 工作階段 (ssh) 至控制站 (主要),請嘗試以下命令 (出現提示時輸入「是」):
[nasadmin@VNX137 ~]$ /nasmcd/sbin/getreason
如果結果顯示:
slot_1 Primary Control station slot_0 Secondary Control station
您必須透過重新啟動 slot_1 控制站來故障回復控制站。以 root (su) 身分登入,並執行下列命令:
[nasadmin@VNX137 ~]# reboot
這需要幾分鐘的時間才能重新啟動控制站,並以原始配置啟動。
控制站回到原始狀態後,請檢查網域檔案:
[nasadmin@VNX137 ~]$ /nasmcd/sbin/getreason 10 - slot_0 primary control station 11 - slot_1 secondary control station 5 - slot_4 contacted 5 - slot_3 contacted [nasadmin@VNX137 ~]$ ll /nas/http/domain total 15 drwxr-xr-x 2 apache apache 1024 Jun 27 14:35 bak drwxr-xr-x 2 apache apache 1024 Nov 14 2013 ldap -rw-r--r-- 1 apache apache 0 Mar 24 22:04 lock_file [nasadmin@VNX137 ~]$
確認控制站主機名稱是否與儲存網域中的主機名稱相同:
[nasadmin@VNX137 ~]$ hostname VNX137 [nasadmin@VNX137 ~]$ hostname -i 10.31.139.137 [nasadmin@VNX137 ~]$ grep initiator /nas/dos/slot_3/boot.cfg setinitiator cs_hostname=Celerra_VNX137 cs_external_ip=10.31.139.137 [nasadmin@VNX137 ~]$ /nas/sbin/navicli -h spa domain -list Node: VNX_137 IP Address: 10.31.139.141 (Master) Name: SPA Port: 80 Secure Port: 443 IP Address: 10.31.139.142 Name: SPB Port: 80 Secure Port: 443 IP Address: 10.31.139.137 Name: Celerra_VNX137 Port: 80 Secure Port: 443 [nasadmin@VNX137 ~]$
如果主要控制站的外部 IP 不相符,請依照文章中 的案例 3 操作,否則 https://support.emc.com/kb/448653 更進一步。
以 root 身分執行以下命令:# /nas/http/webui/bin/domain_admin -i <CS_IP>
# /nas/sbin/naviseccli -h SPA -user sysadmin -password sysadmin -scope 0 domain -messner -add -system <CS_IP>
# /nas/http/webui/bin/update_domain_directory.pl
然後驗證更新的網域檔案:
[nasadmin@VNX137 ~]$ ll /nas/http/domain total 13 drwxr-xr-x 2 apache apache 1024 Sep 1 10:20 bak -rw-r--r-- 1 apache apache 64 Sep 8 12:00 domain_list -rw-r--r-- 1 apache apache 194 Sep 8 12:00 domain_master -rw-r--r-- 1 apache apache 6764 Sep 8 12:00 domain_provider_xml -rw------- 1 apache apache 58 Sep 8 12:00 domain_users -rw-r--r-- 1 apache apache 47 Sep 1 10:20 domain_version drwxr-xr-x 2 apache apache 1024 Nov 14 2013 ldap -rw-r--r-- 1 apache apache 0 Aug 23 14:46 lock_file
現在,登入 Unisphere 以確認警示是否已清除,且檔案選項已啟動。
Affected Products
VNX/VNXeProducts
VNX1 Series, VNX2 Series, VNX5300, VNX5400, VNX5500, VNX5600, VNX5700, VNX5800, VNX7500, VNX7600, VNX8000, VNX/VNXeArticle Properties
Article Number: 000056520
Article Type: Solution
Last Modified: 18 Nov 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.