Dell Unity: Softwareupgrade schlägt mit Integritätsprüfungsfehler fehl:check_replication
Summary: Ein Dell Unity-Softwareupgrade schlägt mit dem Fehler "Health Check Error:check_replication_health_2, check_replication_health_5" fehl. Das Softwareupdate kann auch mit der Meldung "Warnung: check_replication_health_4" fehlschlagen. ...
Symptoms
Integritätsprüfungsmeldungen und Ereigniswarnungen:
FehlerThe health check has failed. One or more remote system problems were detected on the system and causes the upgrade to fail. Record the error code and search the Dell Online Support website for available support options.[Error Code: platform::check_replication_health_2]-------------------------------------Errors-------------------------------------Platform: Check replication healthSync is in progress for the following replication sessions: * VRT_xxxx_xxAction : Cannot perform upgrade while a sync is in progress for a replication session. Please wait until the sync completes or pause the sessions and retry the upgrade.ERROR_CODE=platform::check_replication_health_5|Error|VRT_xxxx_xxEvents > Alerts > Information: The remote system connection is out of date. Update the connection with the latest interface changes.WarningsOne or more replication sessions are configured to be auto-synchronized. This could cause a problem during an upgrade. Pause the replication sessions prior to starting the upgrade and resume them after completing the upgrade. [Warning Code=platform::check_replication_health_4]/nas/log/check_health.161031-152020.log------------------------------------Warnings------------------------------------Platform: Check replication healthThe following replication sessions should be paused prior to starting the upgrade: * rep_sess_res_84_res_1_FNMxxxxxxxxxxx_FNMxxxxxxxxxxx * rep_sess_res_85_res_2_FNMxxxxxxxxxxx_FNMxxxxxxxxxxxAction : Since these are auto-synchronized sessions, they could get into critical state if replication attempts a sync during the upgrade. To avoid this issue, please pause these sessions before starting the upgrade and resume them after the upgrade.ERROR_CODE=platform::check_replication_health_4|Warning|rep_sess_nas_44_nas_1_FNMxxxxxxxxxxx_FNMxxxxxxxxxxx* rep_sess_res_84_res_1_FNMxxxxxxxxxxx_FNMxxxxxxxxxxx* rep_sess_res_85_res_2_FNMxxxxxxxxxxx_FNMxxxxxxxxxxx-------------------------------------Errors-------------------------------------Platform: Check replication healthThe following remote systems have health problems: * FNMxxxxxxxxxxxAction : Escalate this issue through your support organization and provide this output in your escalation.ERROR_CODE=platform::check_replication_health_2|Error|FNMxxxxxxxxxxx--------------------------------------------------------------------------------UPGRADE CANNOT PROCEED.Check Result: Errorspb:~$ uemcli /remote/sys -id RS_1 show -detail |grep Health Health state = Minor failure (15) Health details = "Update the remote system connection to pick up the latest interface changes on the local and remote systems."
Unisphere > Replikationsverbindungen >
Wenn Sie den Mauszeiger über das Warndreieck bewegen, wird Folgendes angezeigt:"Update the remote system connection to pick up the latest interface changes on the local and remote systems."
Cause
- Die zugrunde liegende Ursache für den Fehler bei der Integritätsprüfung ist, dass die Verbindung zwischen den beiden (2) Replikationssystemen aktualisiert werden muss. Die Replikationsverbindungen müssen immer manuell aktualisiert werden, wenn die Storage-Prozessoren (SPs) neu gestartet werden oder der Systemmanagementservice neu gestartet wurde.
- Für die Integritätsprüfungswarnung müssen die Replikationssitzungen auf dem NAS-Server des Quellsystems und jedem einzelnen Dateisystem angehalten werden.
HINWEIS: Durch das Anhalten der Quellseite wird der Replikationsstatus der Zielseite in angehalten geändert.
Resolution
Halten Sie für die Warnmeldung alle Replikationssitzungen vom Quellsystem an, wodurch alle entsprechenden Zielsitzungen angehalten werden:
Lösung: Alle Quellreplikationssitzungen
anhaltenUnisphere-Replikationssitzungen >>> Weitere Aktionen > Anhalten
Aktualisieren Sie für die Fehlermeldung Ihre Replikationsverbindungen>:
Lösung: Remoteverbindung vom Quellsystem
aktualisierenUnisphere-Replikationsverbindungen >>> überprüfen und aktualisieren
HINWEIS: Die Verbindung sollte aktualisiert werden und einen grünen Prüfstatus anzeigen.