NetWorker: NMM 9.1.0.x installasjonsfeil 0x80070643: Kunne ikke kjøre MSI-pakken

Summary: NetWorker: Installasjonsproblem for NetWorker Module for Microsoft 9.1.0.x [Feil 0x80070643: Kunne ikke kjøre MSI-pakke]

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Det er et problem med NetWorker-modulen for installasjon eller oppgradering av Microsoft i følgende miljø.

  • NetWorker Server v8.2.3.8
  • NetWorker Client v8.2.1.7 oppgraderte 8.2.4.4 og oppgraderte senere til 9.1.0.5. (Klient + NMM)
     

FEILKODE:

[7BB8:6648][2017-04-14T00:27:27]e000: Error 0x80070490: BAImpl::OnExecutePackageBegin GetVariableNumeric(StartServices, ...) error!
[7F38:4FD0][2017-04-14T00:27:27]i301: Applying execute package: NMM.msi, action: Modify, path: C:\ProgramData\Package Cache\{B4EEE00F-31E0-4CE3-BF61-8B7500CBCA6D}v9.1.0.4\NMM.msi, arguments: ' ARPSYSTEMCOMPONENT="1" MSIFASTINSTALL="7" RPVNMM_FEATURE="1" NW_SSMS_FEATURE="0" CONFIGFIREWALL="1" INSTALLLEVEL="200" SP_GLR="0" SQL_GLR="0" MOUNTPOINTDIR="C:\Program Files\EMC NetWorker\nsr\tmp\nwfs\NetWorker Virtual File System" HYPERVMOUNTPOINTDIR="C:\Program Files\EMC NetWorker\nsr\tmp" BBBMOUNTPOINTDIR="C:\Program Files\EMC NetWorker\nsr\tmp\BBBMountPoint" SETUPTYPE="Install" INSTCLIENTPUSH="0" ENABLESQLSSMSPLUGINBACKUPTAB="0" ENABLESQLSSMSPLUGINSCRIPT="0" PROXY_RA_PORT="50000" ITEMPOINTVERSION="8.2-RC2" ISUIINSTALL="1" REINSTALL="" ADDLOCAL="RpvNmm_Feature" REMOVE="BurnFlip"'
[7F38:4FD0][2017-04-14T00:27:31]e000: Error 0x80070643: Failed to run maintanance mode for MSI package.
[7F38:4FD0][2017-04-14T00:27:31]e000: Error 0x80070643: Failed to execute MSI package.
[7BB8:6648][2017-04-14T00:27:31]e000: Error 0x80070643: Failed to configure per-machine MSI package.
[7BB8:6648][2017-04-14T00:27:31]i319: Applied execute package: NMM.msi, result: 0x80070643, restart: None
[7BB8:6648][2017-04-14T00:27:31]e000: Error 0x80070643: Failed to execute MSI package.
[7BB8:6648][2017-04-14T00:27:31]e000: Error 0x80070490: BAImpl::OnExecutePackageBegin GetVariableNumeric(StartServices, ...) error!

Cause

På grunn av produktinstallasjonsendring i NetWorker 9.X kreves NetWorker Extended-klientinstallasjonen før NetWorker Module for Microsoft-installasjon og -konfigurasjon.

Resolution

PROSEDYRE:

  • Avinstallere NMM + NetWorker-klient 8.2.4.X fra SQL-noden
  • Installere NetWorker-klienten + NetWorker utvidet-pakken.
Programmer og funksjoner

 

Etter installasjonen vil pakkene bli rapportert i programmer og funksjoner:

Programmer og funksjoner

 

Etter å ha blitt installert, vil dette bli rapportert i programmer og funksjoner:

Programmer og funksjoner

Alternativer for installasjon av NVM

Hvis du vil ha mer informasjon, kan du se NetWorker Module for Microsoft Page:

Affected Products

NetWorker Module for Microsoft

Products

NetWorker Module for Microsoft
Article Properties
Article Number: 000059612
Article Type: Solution
Last Modified: 02 Sep 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.