Connectrix MDS:EXT3-fs 錯誤 (裝置 sdc1): ext3_readdir:目錄 #2 在偏移量 0 處包含一個孔 - 內核

Summary: Connectrix MDS 交換器串流下列錯誤:%KERN-2-SYSTEM_MSG:[63661120.723386] EXT3-fs 錯誤 (裝置 sdc1): ext3_readdir:目錄 #2 在偏移量 0 處包含一個孔洞 - 內核。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Connectrix MDS 交換器串流下列錯誤:

%KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel

在顯示記錄輸出中可看到以下內容:

2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.680361] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.702907] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel

以下內容顯示在顯示系統內部快閃記憶體中:

`show system internal flash`
Mount-on                  1K-blocks      Used   Available   Use%  Filesystem
/                            409600     65564      344036     17   /dev/root
/proc                             0         0           0      0   proc
/sys                              0         0           0      0   none
/isan                       1572864    539352     1033512     35   none
/var                          51200       460       50740      1   none
/etc                           5120      1624        3496     32   none
/nxos/tmp                     51200       336       50864      1   none
/var/log                      51200      8992       42208     18   none
/var/home                      5120         0        5120      0   none
/var/tmp                     307200     11628      295572      4   none
/var/sysmgr                 2097152       124     2097028      1   none
/var/sysmgr/ftp              512000     51968      460032     11   none
/var/sysmgr/srv_logs         102400         0      102400      0   none
/var/sysmgr/ftp/debug_logs     10240         0       10240      0   none
/dev/shm                    1572864    234276     1338588     15   none
/volatile                    512000        12      511988      1   none
/debug                         2048        28        2020      2   none
/dev/mqueue                       0         0           0      0   none
/debugfs                          0         0           0      0   nodev
/mnt/plog                    242430      4458      225455      2   /dev/sdc1
/mnt/fwimg                   121219      4127      110833      4   /dev/sdc3
/mnt/cfg/0                    75797      4729       67154      7   /dev/sda5
/mnt/cfg/1                    75797      4729       67154      7   /dev/sda6
/logflash                  15392672     33064    14577684      1   /dev/sdb1
/bootflash                  3653168    244900     3222696      8   /dev/sda3
/cgroup                           0         0           0      0   vdccontrol
/var/sysmgr/startup-cfg      409600     10272      399328      3   none
/dev/pts                          0         0           0      0   devpts
/mnt/pss                      38156      5482       30704     16   /dev/sda4
/bootflash_sup-remote       3653168    244896     3222704      8   127.1.1.6:/bootflash/

`show module`
Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
2    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok
3    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok
4    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok
5    0      Supervisor module-3                 DS-X97-SF1-K9      active *
6    0      Supervisor module-3                 DS-X97-SF1-K9      ha-standby

`show system redundancy status`
Redundancy mode
---------------
      administrative:   HA
         operational:   HA

This supervisor (sup-1)
-----------------------
    Redundancy state:   Active
    Supervisor state:   Active
      Internal state:   Active with HA standby

Other supervisor (sup-2)
------------------------
    Redundancy state:   Standby
    Supervisor state:   HA standby
      Internal state:   HA standby

 

Cause

快閃記憶體裝置未按照 Cisco 問題「CSCuv67115」掛接。

此問題最初只會發生在處於待機狀態的監管程式上。此問題不會透過 ISSU/D、系統切換或重新載入修正,而且會在處於使用中狀態的監管程式上發現。

Logflash 僅用於儲存除錯命令的輸出。系統穩定運作不需要此程序。

 

Resolution

因應措施:
將受影響的管理引擎重新啟動電源。
在雙監管引擎系統中,這是透過 out-of-service module 命令,並使用 no poweroff module 命令。請確定監管程式處於待機模式,以避免復原影響系統的穩定性。

若要將模組重新開機,電源供應 reloadsystem switchover 命令。

 

例:
命令:

  1. 確認待機監管程式處於 HA 待機狀態:

    show system redundancy status
  2. 關閉待機監管程式模組的電源:

    out-of-service module <standby sup>
  3. 開啟待機監管程式的電源:

    no poweroff <standby sup>
  4. 等待 HA 待命:

    show system redundancy status

監控交換器顯示記錄輸出,以查看 EXT3-fs 錯誤訊息是否仍在交換器上記錄。如果錯誤仍在記錄中,請切換到待機監管程式並重複上述步驟 1-4。

 

Affected Products

Connectrix MDS-Series Hardware

Products

Connectrix MDS-9706, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-Series Hardware
Article Properties
Article Number: 000064345
Article Type: Solution
Last Modified: 17 Sep 2024
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.