Connectrix MDS: EXT3-fs Error (device sdc1): ext3_readdir: directory #2 sisältää reiän kohdassa offset 0 - ydin
Summary: Connectrix MDS -kytkimen virtautuksessa näkyy seuraava virhe: %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs-virhe (laite sdc1): ext3_readdir: hakemistossa #2 on reikä kohdassa offset 0 - ydin. ...
Symptoms
Connectrix MDS -kytkimen virtautuksessa näkyy seuraava virhe:
%KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
Seuraava näkyy ohjelman lokikirjaustuloksessa:
2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.680361] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel 2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.702907] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel 2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
Seuraava näkyy Näytä järjestelmän sisäinen salama:
`show system internal flash` Mount-on 1K-blocks Used Available Use% Filesystem / 409600 65564 344036 17 /dev/root /proc 0 0 0 0 proc /sys 0 0 0 0 none /isan 1572864 539352 1033512 35 none /var 51200 460 50740 1 none /etc 5120 1624 3496 32 none /nxos/tmp 51200 336 50864 1 none /var/log 51200 8992 42208 18 none /var/home 5120 0 5120 0 none /var/tmp 307200 11628 295572 4 none /var/sysmgr 2097152 124 2097028 1 none /var/sysmgr/ftp 512000 51968 460032 11 none /var/sysmgr/srv_logs 102400 0 102400 0 none /var/sysmgr/ftp/debug_logs 10240 0 10240 0 none /dev/shm 1572864 234276 1338588 15 none /volatile 512000 12 511988 1 none /debug 2048 28 2020 2 none /dev/mqueue 0 0 0 0 none /debugfs 0 0 0 0 nodev /mnt/plog 242430 4458 225455 2 /dev/sdc1 /mnt/fwimg 121219 4127 110833 4 /dev/sdc3 /mnt/cfg/0 75797 4729 67154 7 /dev/sda5 /mnt/cfg/1 75797 4729 67154 7 /dev/sda6 /logflash 15392672 33064 14577684 1 /dev/sdb1 /bootflash 3653168 244900 3222696 8 /dev/sda3 /cgroup 0 0 0 0 vdccontrol /var/sysmgr/startup-cfg 409600 10272 399328 3 none /dev/pts 0 0 0 0 devpts /mnt/pss 38156 5482 30704 16 /dev/sda4 /bootflash_sup-remote 3653168 244896 3222704 8 127.1.1.6:/bootflash/ `show module` Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 2 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 3 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 4 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 5 0 Supervisor module-3 DS-X97-SF1-K9 active * 6 0 Supervisor module-3 DS-X97-SF1-K9 ha-standby `show system redundancy status` Redundancy mode --------------- administrative: HA operational: HA This supervisor (sup-1) ----------------------- Redundancy state: Active Supervisor state: Active Internal state: Active with HA standby Other supervisor (sup-2) ------------------------ Redundancy state: Standby Supervisor state: HA standby Internal state: HA standby
Cause
Flash-tallennuslaitetta ei ole asennettu Ciscon ongelman CSCuv67115 mukaisesti.
Ongelma ilmenee aluksi vain valmiustilassa olevilla valvojilla. ISSU/D, järjestelmän vaihto tai uudelleenlataus ei korjaa ongelmaa, ja se havaitaan aktiivisessa tilassa olevan valvojan kohdalla.
Logflashia käytetään vain virheenkorjauskomentojen tulosten tallentamiseen. Sitä ei tarvita järjestelmän vakaaseen toimintaan.
Resolution
Tilapäisratkaisu:
Katkaise ja kytke päälle esimies, jota asia koskee.
Kaksoisvalvontajärjestelmissä tämä tapahtuu sammuttamalla esimies out-of-service module komento ja sen varmuuskopiointi komennolla no poweroff module komento. Varmista, että valvoja on valmiustilassa, jotta palautuminen ei vaikuta järjestelmän vakauteen.
Ei riitä, että moduuli käynnistetään uudelleen reload tai system switchover Komennot.
Esimerkki:
Komennot:
-
Varmista, että varalla oleva valvontahenkilö on HA-valmiustilassa:
show system redundancy status
-
Sammuta valmiustilan valvontamoduuli:
out-of-service module <standby sup>
-
Käynnistä valmiustilan valvontajärjestelmä:
no poweroff <standby sup>
-
Odota HA-valmiustilaa:
show system redundancy status
Tarkkaile kytkimen Show logging -tulosta ja tarkista, kirjautuuko kytkimeen edelleen EXT3-fs-virheilmoitus. Jos virhe kirjautuu edelleen, siirry valmiustilan valvontaan ja toista yllä olevat vaiheet 1–4.