Connectrix MDS: EXT3-fs 오류(디바이스 sdc1): ext3_readdir: 디렉토리 #2에 오프셋 0에 구멍이 있습니다. - 커널

Summary: Connectrix MDS 스위치에서 다음 오류를 스트리밍합니다. %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs 오류(디바이스 sdc1): ext3_readdir: 디렉토리 #2에 오프셋 0 커널에 구멍이 있습니다.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Connectrix MDS 스위치에서 다음 오류를 스트리밍합니다.

%KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel

다음은 show logging 출력에 표시됩니다.

2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.680361] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.702907] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel
2016 Jul 26 19:54:22 Switch Jul 26 19:54:21 %KERN-2-SYSTEM_MSG: [63661120.723386] EXT3-fs error (device sdc1): ext3_readdir: directory #2 contains a hole at offset 0 - kernel

다음은 show system internal flash에 표시됩니다.

`show system internal flash`
Mount-on                  1K-blocks      Used   Available   Use%  Filesystem
/                            409600     65564      344036     17   /dev/root
/proc                             0         0           0      0   proc
/sys                              0         0           0      0   none
/isan                       1572864    539352     1033512     35   none
/var                          51200       460       50740      1   none
/etc                           5120      1624        3496     32   none
/nxos/tmp                     51200       336       50864      1   none
/var/log                      51200      8992       42208     18   none
/var/home                      5120         0        5120      0   none
/var/tmp                     307200     11628      295572      4   none
/var/sysmgr                 2097152       124     2097028      1   none
/var/sysmgr/ftp              512000     51968      460032     11   none
/var/sysmgr/srv_logs         102400         0      102400      0   none
/var/sysmgr/ftp/debug_logs     10240         0       10240      0   none
/dev/shm                    1572864    234276     1338588     15   none
/volatile                    512000        12      511988      1   none
/debug                         2048        28        2020      2   none
/dev/mqueue                       0         0           0      0   none
/debugfs                          0         0           0      0   nodev
/mnt/plog                    242430      4458      225455      2   /dev/sdc1
/mnt/fwimg                   121219      4127      110833      4   /dev/sdc3
/mnt/cfg/0                    75797      4729       67154      7   /dev/sda5
/mnt/cfg/1                    75797      4729       67154      7   /dev/sda6
/logflash                  15392672     33064    14577684      1   /dev/sdb1
/bootflash                  3653168    244900     3222696      8   /dev/sda3
/cgroup                           0         0           0      0   vdccontrol
/var/sysmgr/startup-cfg      409600     10272      399328      3   none
/dev/pts                          0         0           0      0   devpts
/mnt/pss                      38156      5482       30704     16   /dev/sda4
/bootflash_sup-remote       3653168    244896     3222704      8   127.1.1.6:/bootflash/

`show module`
Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
2    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok
3    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok
4    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     ok
5    0      Supervisor module-3                 DS-X97-SF1-K9      active *
6    0      Supervisor module-3                 DS-X97-SF1-K9      ha-standby

`show system redundancy status`
Redundancy mode
---------------
      administrative:   HA
         operational:   HA

This supervisor (sup-1)
-----------------------
    Redundancy state:   Active
    Supervisor state:   Active
      Internal state:   Active with HA standby

Other supervisor (sup-2)
------------------------
    Redundancy state:   Standby
    Supervisor state:   HA standby
      Internal state:   HA standby

 

Cause

플래시 스토리지 디바이스는 Cisco 문제 "CSCuv67115"에 따라 마운트되지 않습니다.

이 문제는 처음에 대기 상태의 수퍼바이저에서만 발생합니다. 이 문제는 ISSU/D, 시스템 전환 또는 재로드로 해결되지 않으며 활성 상태의 수퍼바이저에서 관찰됩니다.

Logflash는 debug 명령의 출력을 저장하는 데만 사용됩니다. 안정적인 시스템 운영을 위해 필요하지 않습니다.

 

Resolution

해결 방법:
영향을 받는 수퍼바이저의 전원을 껐다가 켭니다.
이중 수퍼바이저 시스템에서는 out-of-service module 명령을 실행하고 전원을 다시 켜면 no poweroff module 명령을 사용합니다. 복구가 시스템의 안정성에 영향을 미치지 않도록 수퍼바이저가 대기 모드인지 확인합니다.

다음 경로로 모듈을 재부팅하는 것만으로는 충분하지 않습니다. reload 또는 system switchover 명령을 사용합니다.

 

본보기:
명령을:

  1. 대기 수퍼바이저가 HA 대기 상태인지 확인합니다.

    show system redundancy status
  2. 대기 수퍼바이저 모듈의 전원을 끕니다.

    out-of-service module <standby sup>
  3. 대기 수퍼바이저의 전원을 켭니다.

    no poweroff <standby sup>
  4. HA 대기 대기:

    show system redundancy status

switch show logging 출력을 모니터링하여 EXT3-fs 오류 메시지가 여전히 스위치에 로깅 중인지 확인합니다. 오류가 여전히 로깅 중인 경우 대기 수퍼바이저로 전환하고 위의 1-4단계를 반복합니다.

 

Affected Products

Connectrix MDS-Series Hardware

Products

Connectrix MDS-9706, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-Series Hardware
Article Properties
Article Number: 000064345
Article Type: Solution
Last Modified: 17 Sep 2024
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.