Cisco: fan speed high and will not return to normal limits

Summary: Cisco: fan speed high and will not return to normal limits

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

replace the original sfp with Cisco "compatible" long wave GBIC.
 

Fan speed on 9148S goes high after 30 minutes, and will not return to normal.

The cause of a fan speed issue is seen as:
1) High system temperature (could be blockage but not necessarily so)
2) Any SFP temp alarm
3) Any system fan failure

There was no observed blockage or impediment.
There were no sfp alarm, nor a system fan failure.





Cause

Customer replaced sfp with long wave GBIC (Cisco compatible).
This sfp was not able to be properly read by the switch, and caused the fan speed issue.

Resolution

use Cisco part. Upon replacing or removing sfp, speed returned to normal limits  within 30 mins.

Affected Products

Connectrix MDS-9148S

Products

Connectrix MDS-9148S
Article Properties
Article Number: 000064622
Article Type: Solution
Last Modified: 13 Mar 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.