Isilon:缺少/故障 M2 存放庫介面卡的第 6 代節點節點韌體更新立即發生錯誤
Summary: Isilon:缺少/故障 M2 存放庫介面卡的第 6 代節點節點韌體更新立即發生錯誤
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
第 6 代節點需要在每個節點中使用 M.2 存放庫卡來執行節點韌體更新。 如果 M.2 存放庫卡遺失或故障,嘗試在這些節點上執行節點韌體更新時將會發生錯誤。
除了升級檢視中的錯誤之外,發生錯誤的節點上的記錄檔 /var/log/isi_firmware.log 會有一行包含類似以下內容的「no a 0」:
2020-01-01 04:54:25,169 INFO [11111] : FW action: Cleaning up fw partition
2020-01-01 04:54:25,170 INFO [11111] : FW action: toggle_debug: off
2020-01-01 04:54:25,241 INFO [11111] : FW action: Updating Node 1
2020-01-01 04:54:25,263 INFO [11111] : Updating device EPssp_infinity
2020-01-01 04:54:25,263 INFO [22222] : <rpc> EPssp_infinity(EPssp_infinity): version=02.50 target=02.81
2020-01-01 04:54:25,264 INFO [11111] : Updating Firmware EPssp_infinity - old: 02.50 new : 02.81
2020-01-01 04:54:25,526 ERROR [11111] : Node 1: 'no such object ada0'
2020-01-01 04:54:25,565 INFO [11111] : FW action: Cleaning up fw partition
2020-01-01 04:54:25,565 INFO [11111] : FW action: toggle_debug: offCause
遺失存放庫卡
Resolution
發生這種情況時,應更換節點上的 M.2 存放庫卡。
Additional Information
Isilon 叢集上分析執行狀況檢查指令檔包含一項檢查,可識別 M.2 存放庫介面卡遺失或超過其 SMART 狀態閾值,並可能報告類似下列結果:
Vault Card FAIL FAIL: The vault card located at ada0 in the following Generation 6 nodes are not reporting in the output of camcontrol devlist: 1 FAIL: The vault card located at ada0 in the following Generation 6 nodes are reporting SMART status is threshold exceeded: 1
To run only the check for the Vault Card, use the following additional argument when running the Isilon On-Cluster Analysis tool: --run=checkVaultCard
Affected Products
Isilon Gen6Products
Isilon Gen6Article Properties
Article Number: 000082048
Article Type: Solution
Last Modified: 03 Mar 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.