PowerFlex 3.0: OpenStack Cinder no se puede conectar a la puerta de enlace de API REST
Summary: El controlador Cinder no puede comunicarse con el gateway mediante la API REST.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
IM Gateway cierra las conexiones antes de tiempo (durante la negociación de TLS). Se pueden observar errores similares en los registros de Cinder:
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager [req-cdb7ea5a-f422-48f9-bf12-9bd351f519f4 - - - - -] Failed to initialize driver.: requests.exceptions.ConnectionError: ('Connection aborted.', RemoteDisconnected('Remote end closed
connection without response',))
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager Traceback (most recent call last):
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 672, in urlopen
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager chunked=chunked,
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 421, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager six.raise_from(e, None)
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "", line 3, in raise_from
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 416, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager httplib_response = conn.getresponse()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 1354, in getresponse
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager response.begin()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 307, in begin
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager version, status, reason = self._read_status()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 276, in _read_status
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager raise RemoteDisconnected("Remote end closed connection without"
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager http.client.RemoteDisconnected: Remote end closed connection without response
Impacto
No se puede administrar el entorno de VxFlex OS.
Cause
La versión incorrecta de Java está instalada en el servidor de la puerta de enlace de IM.
En este caso, se utilizó OpenJDK, mientras que PowerFlex OS 3.0.x solo es compatible con Oracle Java.
Resolution
Instale la versión de Oracle Java soportada.
Consulte la Guía de implementación de PowerFlex para conocer las versiones compatibles.
Versiones afectadas
PowerFlex OS 3.x: antes de PowerFlex 3.5
Problema corregido en la versión
No es un problema de PowerFlex, sino de compatibilidad A partir de PowerFlex 3.5, ahora se admite OpenJDK.
Additional Information
Affected Products
PowerFlex SoftwareProducts
PowerFlex Software, VxFlex Product Family, VxFlex Ready NodeArticle Properties
Article Number: 000082224
Article Type: Solution
Last Modified: 24 Nov 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.