PowerFlex 3.0: OpenStack Cinder non è in grado di connettersi al gateway API REST

Summary: Il driver cinder non è in grado di comunicare con il gateway utilizzando l'API REST.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Il gateway IM chiude le connessioni in modo anomalo (durante la negoziazione TLS). Errori simili possono essere osservati nei registri cinder:

 
 2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager [req-cdb7ea5a-f422-48f9-bf12-9bd351f519f4 - - - - -] Failed to initialize driver.: requests.exceptions.ConnectionError: ('Connection aborted.', RemoteDisconnected('Remote end closed
connection without response',))
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager Traceback (most recent call last):
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 672, in urlopen
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager chunked=chunked,
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 421, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager six.raise_from(e, None)
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "", line 3, in raise_from
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 416, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager httplib_response = conn.getresponse()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 1354, in getresponse
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager response.begin()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 307, in begin
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager version, status, reason = self._read_status()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 276, in _read_status
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager raise RemoteDisconnected("Remote end closed connection without"
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager http.client.RemoteDisconnected: Remote end closed connection without response

 

Impatto

Impossibile gestire l'ambiente VxFlex OS.

Cause

La versione di Java errata è installata sul server
gateway IM.In questo caso è stato utilizzato OpenJDK, mentre PowerFlex OS 3.0.x supporta solo Oracle Java.

 

Resolution

Installare la versione supportata di Oracle Java.
Consultare la Guida al deployment di PowerFlex per le versioni supportate.

 

Versioni interessate

PowerFlex OS 3.x - prima di PowerFlex 3.5

Risolto nella versione

Non si tratta di PowerFlex, bensì di un problema di compatibilità A partire da PowerFlex 3.5, OpenJDK è ora supportato.

 

Additional Information

 

 

Affected Products

PowerFlex Software

Products

PowerFlex Software, VxFlex Product Family, VxFlex Ready Node
Article Properties
Article Number: 000082224
Article Type: Solution
Last Modified: 24 Nov 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.