PowerFlex 3.0: OpenStack Cinder kan ikke koble til REST API Gateway
Summary: Cinder-driveren kan ikke snakke med gatewayen ved hjelp av REST API.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Gateway for direktemelding lukker tilkoblingene for tidlig (under TLS-forhandlinger). Lignende feil kan observeres i cinder-loggene:
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager [req-cdb7ea5a-f422-48f9-bf12-9bd351f519f4 - - - - -] Failed to initialize driver.: requests.exceptions.ConnectionError: ('Connection aborted.', RemoteDisconnected('Remote end closed
connection without response',))
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager Traceback (most recent call last):
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 672, in urlopen
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager chunked=chunked,
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 421, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager six.raise_from(e, None)
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "", line 3, in raise_from
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 416, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager httplib_response = conn.getresponse()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 1354, in getresponse
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager response.begin()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 307, in begin
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager version, status, reason = self._read_status()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 276, in _read_status
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager raise RemoteDisconnected("Remote end closed connection without"
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager http.client.RemoteDisconnected: Remote end closed connection without response
Innvirkning
Kan ikke administrere VxFlex OS-miljøet.
Cause
Feil Java-versjon er installert på IM Gateway-serveren.
I dette tilfellet ble OpenJDK brukt, mens PowerFlex OS 3.0.x bare støtter Oracle Java.
Resolution
Installer støttet Oracle Java-versjon.
Se implementeringsveiledning for PowerFlex for støttede versjoner.
Berørte versjoner
PowerFlex OS 3.x – før PowerFlex 3.5
Løst i versjon
Ikke en PowerFlex, snarere et kompatibilitetsproblem Fra og med PowerFlex 3.5 støttes OpenJDK nå.
Additional Information
Affected Products
PowerFlex SoftwareProducts
PowerFlex Software, VxFlex Product Family, VxFlex Ready NodeArticle Properties
Article Number: 000082224
Article Type: Solution
Last Modified: 24 Nov 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.