PowerFlex 3.0: O OpenStack Cinder não consegue se conectar ao gateway da API REST

Summary: O driver mais recente não consegue se comunicar com o gateway usando a API REST.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

O gateway de IM fecha as conexões prematuramente (durante a negociação TLS). Erros semelhantes podem ser observados nos logs de cinza:

 
 2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager [req-cdb7ea5a-f422-48f9-bf12-9bd351f519f4 - - - - -] Failed to initialize driver.: requests.exceptions.ConnectionError: ('Connection aborted.', RemoteDisconnected('Remote end closed
connection without response',))
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager Traceback (most recent call last):
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 672, in urlopen
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager chunked=chunked,
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 421, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager six.raise_from(e, None)
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "", line 3, in raise_from
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib/python3.6/site-packages/urllib3/connectionpool.py", line 416, in _make_request
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager httplib_response = conn.getresponse()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 1354, in getresponse
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager response.begin()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 307, in begin
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager version, status, reason = self._read_status()
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager File "/usr/lib64/python3.6/http/client.py", line 276, in _read_status
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager raise RemoteDisconnected("Remote end closed connection without"
2020-03-25 20:11:43.569 34 ERROR cinder.volume.manager http.client.RemoteDisconnected: Remote end closed connection without response

 

Impacto

Não é possível gerenciar o ambiente do VxFlex OS.

Cause

A versão incorreta do Java é instalada no servidor de gateway do IM.
Nesse caso, o OpenJDK foi usado, enquanto o PowerFlex OS 3.0.x é compatível apenas com Oracle Java.

 

Resolution

Instale a versão compatível do Oracle Java.
Consulte o Guia de implementação do PowerFlex para obter as versões compatíveis.

 

Versões afetadas

PowerFlex OS 3.x - antes do PowerFlex 3.5

Correção feita na versão

Não é um PowerFlex, mas sim um problema de compatibilidade A partir do PowerFlex 3.5, agora há suporte para OpenJDK.

 

Additional Information

 

 

Affected Products

PowerFlex Software

Products

PowerFlex Software, VxFlex Product Family, VxFlex Ready Node
Article Properties
Article Number: 000082224
Article Type: Solution
Last Modified: 24 Nov 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.