Compellent: Storage Center Alert: Disk has only one path to device
Summary: Compellent: Storage Center Alert: Disk has only one path to device
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
If multiple alerts are received for several different disks with the same message, check for the following:
For a Single Disk Alert:
Each disk should have two paths for I/O. One of those paths for the disk indicated in the alert has become unavailable.
To identify the physical location of the disk(s) and verify status:
- other alerts that may indicate / isolate where the issue is
- the status of enclosure I/O modules
- the cabling to the enclosures
- the status of I/O ports on the controllers that connect to the enclosures
For a Single Disk Alert:
Each disk should have two paths for I/O. One of those paths for the disk indicated in the alert has become unavailable.
To identify the physical location of the disk(s) and verify status:
- Go to Storage Tab in Dell Storage Manager
- Expand Disks / Disk Folder
- Look for the disk index number indicated in the alert.
- Record the enclosure number and enclosure position the disk is located
- Right click disk and choose ‘Show in Hardware Tab’
- Review status of ‘Bypass A Side’ and ‘Bypass B Side’
- If both sides show ‘No’, the issue has cleared, acknowledge alert
- If one of the sides show ‘Yes’, the disk still has one path available, contact technical support for additional help
Affected Products
Compellent (SC, SCv & FS Series), Dell Storage SCv2000, Dell Storage SCv2020, Dell Storage SCv2080, Dell Storage SC9000Article Properties
Article Number: 000115468