Symptoms
在 PowerEdge 服务器的 PCI 总线上发生致命错误后,Windows 服务器上发生停止错误 WHEA_UNCORRECTABLE_ERROR (124)。
系统事件日志显示:
Log Name: System Source: Microsoft-Windows-WER-SystemErrorReporting Date: 4/01/2014 9:00:12 AM Event ID: 1001 Task Category: None Level: Information Keywords: Classic User: N/A Computer: computername.domainname.local Description: The computer has rebooted from a bugcheck. The bugcheck was: 0x00000124 (0x0000000000000005, 0xfffffa800d0ce028, 0x0000000000000000, 0x0000000000000000). A dump was saved in: C:\Windows\MEMORY.DMP. Report Id: 031614-31356-01
PowerEdge 服务器的硬件日志包含类似于以下内容的条目,指示 PCI 总线上存在致命错误。
Sun Mar 16 03:28:02 2014 A bus fatal error was detected on a component at bus 0 device 2 function 0. 0x030002421A2553B1000413186FAA1000h Sun Mar 16 03:28:02 2014 A bus fatal error was detected on a component at slot 5. 0x020002421A2553B1000413186FAA0085h生成的转储文件包含类似于以下内容的信息:
WHEA_UNCORRECTABLE_ERROR (124) A fatal hardware error has occurred. Parameter 1 identifies the type of error source that reported the error. Parameter 2 holds the address of the WHEA_ERROR_RECORD structure that describes the error condition. Arguments: Arg1: 0000000000000005, Generic Error Arg2: fffffa800d0ce028, Address of the WHEA_ERROR_RECORD structure. Arg3: 0000000000000000 Arg4: 0000000000000000 Debugging Details: ------------------ BUGCHECK_STR: 0x124_GenuineIntel CUSTOMER_CRASH_COUNT: 1 DEFAULT_BUCKET_ID: WIN7_DRIVER_FAULT_SERVER CURRENT_IRQL: 0 STACK_COMMAND: kb FOLLOWUP_NAME: MachineOwner MODULE_NAME: GenuineIntel IMAGE_NAME: GenuineIntel DEBUG_FLR_IMAGE_TIMESTAMP: 0 FAILURE_BUCKET_ID: X64_0x124_GenuineIntel_PCIEXPRESS BUCKET_ID: X64_0x124_GenuineIntel_PCIEXPRESS
Cause
硬件问题导致此问题。
Stop error 0x124 (WHEA_UNCORRECTABLE_ERROR)
Resolution
- 确定导致PCI总线严重错误的硬件组件。重新拔插设备和显示器。
- 对导致 PCI 总线严重错误的硬件组件执行诊断,如果有缺陷则进行更换。
- 卸下其他插槽中安装的任何其他 PCI 设备。启动服务器并进行监视。
- 重新拔插处理器、引导服务器并进行监视。
- 对主板和处理器执行诊断。
- 更换发现有缺陷的设备。
Affected Products
Microsoft Windows Server 2016, Microsoft Windows Server 2019, Microsoft Windows Server 2022, Microsoft Windows 2012 Server, Microsoft Windows 2012 Server R2Products
PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerEdge R240, PowerEdge R250, PowerEdge R260, PowerEdge R340, PowerEdge R350, PowerEdge R360, PowerEdge R440, PowerEdge R450
, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T140, PowerEdge T150, PowerEdge T160, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640
...
Article Properties
Article Number: 000137619
Article Type: Solution
Last Modified: 10 Dec 2024
Version: 8
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.