PowerScale:SyncIQ 原則無法啟動。出現未知原則錯誤訊息。
Summary: 本 KB 文章解決 SyncIQ 排程器程序 (isi_migr_sched) 未執行的罕見問題。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
SyncIQ 原則無法手動啟動。下列錯誤訊息隨即顯示:
isilon01-2# isi sync jobs start Test_Replication An unknown policy error occurred: Check the status of the job on the target cluster and source
Cause
發生此故障的原因是 the isi_migr_sched 程序未在所有節點上執行。
Resolution
執行下列命令,以確認 SyncIQ 排程器是否正在所有節點上執行:
# isi_for_array -s 'ps alwx | grep isi_migr_sched'
如果未在所有節點上執行,請嘗試下列任何解決方案:
- 停用然後啟用 SyncIQ 服務 (
isi_migrate):
# isi services -a isi_migrate disable # isi services -a isi_migrate enable
2.啟動 isi_migr_sched 手動處理。
# isi_for_array -s '/usr/bin/isi_migr_sched'
3.確認 isi_migr_sched 正在所有節點上執行。
# isi_for_array -s ps auwx | grep isi_migr_sched
Affected Products
Isilon, PowerScale OneFS, Isilon SyncIQArticle Properties