Symptoms

SyncIQ 策略无法手动启动。显示以下错误消息:  

isilon01-2# isi sync jobs start Test_Replication 
An unknown policy error occurred: Check the status of the job on the target cluster and source

Cause

发生此故障的原因是 the isi_migr_sched 进程未在所有节点上运行。

Resolution

运行以下命令以验证 SyncIQ 计划程序是否正在所有节点上运行:

# isi_for_array -s 'ps alwx | grep isi_migr_sched'


如果它未在所有节点上运行,请尝试以下任何解决方案: 

  1. 禁用然后启用 SyncIQ 服务(isi_migrate):
# isi services -a isi_migrate disable
# isi services -a isi_migrate enable


      2.启动 isi_migr_sched 手动处理。

# isi_for_array -s '/usr/bin/isi_migr_sched'


      3.验证 isi_migr_sched 正在所有节点上运行。

# isi_for_array -s ps auwx | grep isi_migr_sched

 