VPLEX:無法在 GUI 和 CLI 中檢視分散式裝置詳細資料
Summary: 分散式裝置的詳細資料不會列在 GUI 和 CLI 的上下文中
Symptoms
在 VPlex 分散式裝置環境中發出長清單命令時,DD 詳細資料不會列在 DD 狀況良好且處於執行狀態的 CLI 中。甚至 GUI 也不會反映 DD 詳細資料
CLI 輸出:
VPlexcli:/distributed-storage/distributed-devices> ll
VPlexcli:/distributed-storage/distributed-devices>
GUI 輸出:
在 CLI 中檢查 show-use-hierarchy,並直接輸入 DD 名稱內容,就會列出 DD 資訊。同樣地,在 GUI 檢視對應中也會顯示 DD 詳細資料。
CLI 輸出:
show-use-hierarchy --targets /clusters/cluster-1/virtual-volumes/dev_test_claim_vol
virtual-volume: dev_test_claim_vol (1G, distributed @ cluster-1, unexported)
distributed-device: dev_test_claim (1G, raid-1)
distributed-device-component: dev_test_claim2017Feb16_141533 (1G, raid-0, cluster-1)
extent: extent_test_claim_1 (1G)
storage-volume: test_claim (1G)
logical-unit: VPD83T3:6006016013302700bcf5c222512fe611
storage-array: EMC-CLARiiON-APMxxxxxxxxxxx
distributed-device-component: dm_test_1 (1G, raid-0, cluster-2)
extent: extent_CLARiiON1782_LUN_00036_1 (1G)
storage-volume: CLARiiON1782_LUN_00036 (1G)
logical-unit: VPD83T3:6006016013302700be111d339b08e611
storage-array: EMC-CLARiiON-APMxxxxxxxxxxx
VPlexcli:/distributed-storage/distributed-devices/dev_test_claim> ll
Attributes:
Name Value
---------------------- ----------------------
application-consistent false
auto-resume true
block-count 262144
block-size 4K
capacity 1G
clusters-involved [cluster-1, cluster-2]
geometry raid-1
health-indications []
health-state ok
locality distributed
operational-status ok
rebuild-allowed true
rebuild-eta -
rebuild-progress -
rebuild-status done
rebuild-type full
rule-set-name cluster-1-detaches
service-status running
stripe-depth -
system-id dev_test_claim
thin-capable false
transfer-size 128K
virtual-volume dev_test_claim_vol
Contexts:
Name Description
----------------------------- ------------------------------------------------
at-cluster Contains cluster-specific information on the
enclosing distributed-device.
distributed-device-components Contains information about one cluster-local leg
of the enclosing distributed-device.
GUI 輸出:
Cause
VPlex Geosynchrony 中的程式碼錯誤
Resolution
列出 DD 的問題來自 VPlex GeoSynchrony 6.0 版本。
在 6.0 版本中,當分散式裝置的數量不超過一個時,在 VPlex 中列出的分散式裝置將會失敗。
如果 DD 的數量只有一個,則在 GUI 和 CLI 中列出 DD 時將會發生問題。如果 DD 計數超過一個,則列出 DD 不會有任何問題。因此,因應措施是建立多個 DD,並檢查 DD 詳細資料。
此問題已在 VPlex GeoSynchrony 6.0 Service Pack1 修補程式 1 中解決。