VPLEX: VMware Storage VMotion Fail reporting Loss of volume access on VPlex
Summary: A storage VMotion task failed, of a VM from a datastore to a new datastore, both presented by VPlex
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
A storage VMotion task failed, of a VM from a datastore to a new datastore, both presented by VPlex. User encounter the following error message:
Loss of volume access 5xxxxxxx-xxxxxxxx-xxxx-xxxxxxxxxxxx (Vxxxxxxxxxx1) because of Connectivity issues. An attempt to Is in progress and the result will be transmitted to very soon.
On VPlex a stream of stdf/41 in the firmware logs against the target datastore LUN.
xxx.xxx.xxx.68/cpu0/log:5988:W/"00601661363310745-2":3157776:<4>2017/02/15 14:19:37.29: stdf/41 xcopy malformed command, target lu not supported, ITL fcp: (0x100000xxxxxxxxxx)(0x500014xxxxxxxxxx)(0x0, VPD83T3:6000144xxxxxxxxxxxxxxxxxxxxxxxxx)
Cause
stdf/41 event "xcopy malformed command, target lu not supported" would be logged if any of the following conditions are met:
The xcopy command which arrives on a director should have both the source and target LU to be in exported state, i.e. both source LU and target LU must be exported through the same directors in the storage views.
NOTE: The stdf/41 event currently prints the LUN on which the xcopy CDB has arrived i.e. target LU, the customer should advise on the source LUN.
- WWN provided in the target descriptor does not correspond to any LU.
- STDFLU private data pointer is NULL.
- If the LU is not exported. (Does not belong to a storage view or not masked through this director)
The xcopy command which arrives on a director should have both the source and target LU to be in exported state, i.e. both source LU and target LU must be exported through the same directors in the storage views.
NOTE: The stdf/41 event currently prints the LUN on which the xcopy CDB has arrived i.e. target LU, the customer should advise on the source LUN.
Resolution
Confirm that both source LU and target LU must be exported through the same directors in the storage views.
Affected Products
VPLEX SeriesProducts
VPLEX GeoSynchrony, VPLEX Series, VPLEX VS1, VPLEX VS2, VPLEX VS6Article Properties
Article Number: 000168112
Article Type: Solution
Last Modified: 20 Nov 2020
Version: 2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.