VPLEX:無法從 VPLEX UI 或 CLI 移除已解除委任的儲存陣列
Summary: 本文討論從 VPLEX 移除陣列後出現的過時或幻像陣列,以及移除幻像陣列要採取的步驟。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
為 VPLEX 叢集設定多個相同型號的陣列,然後將一或多個陣列解除委任並從 VPLEX 移除。如果仍為 VPLEX 叢集設定至少一個相同的陣列,則可能會觸發本知識文章中所述的狀況。
最終使用者已從 VPLEX 中停用一或多個儲存陣列 (但並非通用型號的所有陣列),以及一或多個舊陣列仍會出現在 UI 和 CLI 中。
若要查看哪些陣列仍顯示為幻像陣列,請在 VPlexcli 速:
VPlexcli:/> ll /clusters/cluster-1/storage-elements/storage-arrays /clusters/cluster-1/storage-elements/storage-arrays: Name Connectivity Auto Ports Logical ------------------------------- Status Switch ------------------- Unit ------------------------------- ------------ ------ ------------------- Count ------------------------------- ------------ ------ ------------------- ------- EMC-SYMMETRIX-111111111 ok - 0x500009xxxxxxxxx1, 28 0x500009xxxxxxxxx2, 0x500009xxxxxxxxx3, 0x500009xxxxxxxxx4 XtremIO-XtremApp- error - 0 XtremIO-XtremApp-FNM11111111111 ok - 0x514xxxxxxxxxxxx0, 9 0x514xxxxxxxxxxxx1, 0x514xxxxxxxxxxxx4, 0x514xxxxxxxxxxxx5
解除委任或移除的陣列 (通常是 XtremIO 或 Symmetrix) 顯示「error」,沒有序號,也沒有連接埠和「0」邏輯單元,且應已從 VPLEX 中取消分區。
注意:使用者應使用 SolVe Online 的「從 VPLEX 移除磁碟或陣列」程序,位於「其他 >管理員>VPLEX 管理員程序>」下 隨時管理他們想要從 VPLEX 移除磁碟或陣列。
Cause
如果未佈建 LUN0,儲存陣列會以非唯一的 LU ID 回應至 INQ VPD83。因此,具有啟動器目標 (IT) 但沒有隨需分配 LUN 的多個相同型號陣列,最終會對預設 LUN0 具有相同的 LU ID。嘗試從 VPLEX 解除其中一個陣列時,這會導致問題。
如果其餘儲存陣列沒有實際的 LUN0,就會遇到此問題。
檢查邏輯單元 (在
不含 LUN0 的範例:
如果其餘儲存陣列沒有實際的 LUN0,就會遇到此問題。
檢查邏輯單元 (在
VPlexcli),然後檢查「LUN」欄。如果沒有 0x0000000000000000 項目,則表示沒有從該陣列隨需分配真正的 LUN0:
不含 LUN0 的範例:
VPlexcli:/cluster-1/storage-elements/storage-arrays/XtremIO-XtremApp-FNM11111111111/logical-units> ll /clusters/cluster-1/storage-elements/storage-arrays/XtremIO-XtremApp-FNM11111111111/logical-units: Name Connectivity Active/AAO Passive/AAN Visibility LUNs ALUA ------------------------------------------ Status Controllers Controllers ---------- ------------------ Support ------------------------------------------ ---------------- -------------------- ----------- ---------- ------------------ ------- VPD83T3:514xxxxxxxxxxxx1 ok FNM11111111111 active 0x0001000000000000 none VPD83T3:514xxxxxxxxxxxx2 ok FNM11111111111 active 0x0002000000000000 none VPD83T3:514xxxxxxxxxxxx3 ok FNM11111111111 active 0x0003000000000000 none具有 LUN0 的範例:
VPlexcli:/cluster-1/storage-elements/storage-arrays/XtremIO-XtremApp-FNM11111111111/logical-units> ll /clusters/cluster-1/storage-elements/storage-arrays/XtremIO-XtremApp-FNM11111111111/logical-units: Name Connectivity Active/AAO Passive/AAN Visibility LUNs ALUA Status Controllers Controllers ---------- ------------------ Support VPD83T3:514xxxxxxxxxxxx0 ok FNM11111111111 active 0x0000000000000000 none VPD83T3:514xxxxxxxxxxxx1 ok FNM11111111111 active 0x0001000000000000 none VPD83T3:514xxxxxxxxxxxx2 ok FNM11111111111 active 0x0002000000000000 none VPD83T3:514xxxxxxxxxxxx3 ok FNM11111111111 active 0x0003000000000000 none
Resolution
對於所有未解除委任的其餘相同陣列,使用者必須進入陣列並向 VPLEX 顯示 LUN0。完成後,如果 VPLEX 上仍設定多個陣列,請逐一重新探索 VPLEX 中的陣列。如果在基礎陣列上配置了多個存儲組或掩碼檢視,則每個都需要自己的唯一 LUN0。目標是讓 VPLEX 和儲存陣列之間的每個分區路徑都已佈建 LUN0。一旦針對所有其他陣列執行此作業,應從 VPLEX CLI 或 UI 中自動移除較舊或已解除代理的陣列。
如果在按照本文中的說明操作後,問題仍然存在,請聯絡 Dell 支援 並提及本文。
值得一提的是,這是外觀警示,不會影響 VPLEX 的功能。將問題保持原樣而不承擔後果是可以接受的。
此問題通常會在下列情況期間自行解決:
如果在按照本文中的說明操作後,問題仍然存在,請聯絡 Dell 支援 並提及本文。
值得一提的是,這是外觀警示,不會影響 VPLEX 的功能。將問題保持原樣而不承擔後果是可以接受的。
此問題通常會在下列情況期間自行解決:
- VPLEX 不中斷升級 (NDU) 或升級
- VPLEX 導向器韌體輪流重新開機
- 計畫內電源維護,關閉導向器韌體,然後重新開啟
Additional Information
確定所有分區至 VPLEX 的目標連接埠也已遮罩在陣列上。這可確保所有 IT 至少可以使用真正的 LUN0 進行佈建。如果未佈建 LUN0,陣列可以使用非唯一的 LU ID 回應 INQ VPD83。因此,多個完全相同的陣列若 IT 中沒有隨需分配的 LUN,最終會使用相同的 LU ID 作為預設 LUN0。嘗試從 VPLEX 解除其中一個陣列時,這會導致問題。已看到 (但不限於) 佈建至 VPLEX 的 XtremIO、Symmetrix 或 VMAX 陣列。