Unisphere for PowerMax: Virhe asennettaessa VC Redistributable -ohjelmistoa, kun Unisphere for PowerMax 9.1 päivitetään versioon 9.2
Summary: Virhe asennettaessa VC Redistributable -ohjelmistoa, kun Unisphere for PowerMax 9.1 päivitetään versioon 9.2
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Instructions
Oireet:
Unispheren päivittäminen PowerMax 9.1:stä versioon 9.2
Virhe asennettaessa VC Redistributable
Unisphere -asennuslokien raportteja:
Installation: Unsuccessful.25691 Successes0 Warnings0 NonFatalErrors1 FatalErrorsError installing VC RedistributableCustom Action: com.emc.ia.spa.actions.InstallVCRedistActionStatus: FATAL ERRORAdditional Notes: FATAL ERROR - class com.emc.ia.spa.actions.InstallVCRedistAction FatalInstallException: nullINSTALL_SUCCESS=FATAL_ERROR
Cause:
EMC-ohjelmiston rekisteritiedosto ei sisällä Unisphere for PowerMaxia.
Koska nämä tiedot otetaan rekisteristä, Windows-käyttöjärjestelmän rekisteri ei tunnista Unisphere for PowerMaxia asennetuksi.
Järjestelmän tapahtumalokia tarkasteltaessa näyttää siltä, että käyttöjärjestelmässä saattaa olla FS:n vioittumisongelmia N:lle: ja useat palvelut eivät käynnisty tai aikakatkaistaan:
05/19/2021 02:35:50 PM Information P3TWDVIS02STD.gr 7036 Service Control Manager The WMI Performance Adapter service entered the running state.05/19/2021 02:35:49 PM Error P3TWDVIS02STD.gr 55 Ntfs A corruption was discovered in the file system structure on volume N:. The exact nature of the corruption is unknown. The file system structures need to be scanned online.05/19/2021 02:35:49 PM Information P3TWDVIS02STD.gr 7036 Service Control Manager The EMC Symmetrix Management Application Server service entered the stopped state.05/18/2021 04:14:48 PM Error P3TWDVIS02STD.gr 7000 Service Control Manager The EMC storapid service failed to start due to the following error: The service did not respond to the start or control request in a timely fashion.05/18/2021 04:14:48 PM Error P3TWDVIS02STD.gr 7009 Service Control Manager A timeout was reached (30000 milliseconds) while waiting for the EMC storapid service to connect.05/19/2021 11:46:04 AM Error P3TWDVIS02STD.gr 7001 Service Control Manager The Network Connectivity Assistant service depends on the IP Helper service which failed to start because of the following error: The dependency service or group failed to start.
Ratkaisu:
- Poista Unispheren asennus
- Asenna VC++ 2015
- Asenna Unisphere uudelleen