Unisphere для PowerMax. Ошибка установки распространяемого пакета VC при модернизации Unisphere для PowerMax 9.1 до версии 9.2

Summary: Ошибка установки распространяемого пакета VC при модернизации Unisphere для PowerMax 9.1 до версии 9.2

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Instructions

Симптомы:
Обновление Unisphere для PowerMax 9.1 до версии 9.2
Ошибка при установке распространяемого пакета

VCОтчеты журналов установки Unisphere следующие.


Installation: Unsuccessful.

25691 Successes
0 Warnings
0 NonFatalErrors
1 FatalErrors

Error installing VC Redistributable

Custom Action:            com.emc.ia.spa.actions.InstallVCRedistAction
                          Status: FATAL ERROR
                          Additional Notes: FATAL ERROR -     class com.emc.ia.spa.actions.InstallVCRedistAction FatalInstallException: null
                          
                          INSTALL_SUCCESS=FATAL_ERROR

Причина.


Файл реестра программного обеспечения EMC не содержит Unisphere для PowerMax.

Так как эта информация берется из реестра, реестр ОС Windows не распознает установленное ПО Unisphere для PowerMax.

При просмотре журнала системных событий может показаться, что в ОС могут быть проблемы с повреждением файловой системы для N:, а также несколько служб не запускаются или время ожидания истекает:


05/19/2021 02:35:50 PM  Information   P3TWDVIS02STD.gr 7036    Service Control Manager          The WMI Performance Adapter service entered the running state.
05/19/2021 02:35:49 PM  Error         P3TWDVIS02STD.gr 55      Ntfs                             A corruption was discovered in the file system structure on volume N:.    The exact nature of the corruption is unknown.  The file system structures need to be scanned online. 
05/19/2021 02:35:49 PM  Information   P3TWDVIS02STD.gr 7036    Service Control Manager          The EMC Symmetrix Management Application Server service entered the stopped state.

05/18/2021 04:14:48 PM  Error         P3TWDVIS02STD.gr 7000    Service Control Manager          The EMC storapid service failed to start due to the following error:   The service did not respond to the start or control request in a timely fashion.
05/18/2021 04:14:48 PM  Error         P3TWDVIS02STD.gr 7009    Service Control Manager          A timeout was reached (30000 milliseconds) while waiting for the EMC storapid service to connect.

05/19/2021 11:46:04 AM  Error         P3TWDVIS02STD.gr 7001    Service Control Manager          The Network Connectivity Assistant service depends on the IP Helper service which failed to start because of the following error:   The dependency service or group failed to start.

Решение.

  • Удаление Unisphere
  • Установка VC++ 2015