Connectrix:Cisco MDS:「PLATFORM-1-PFM_ALERT:FAN_BAD錯誤地記錄缺席風扇的事件
Summary: 切換流式處理「%PLATFORM-1-PFM_ALERT:為缺席的粉絲舉辦FAN_BAD」相關活動
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- 在執行 8.3(1) 的交換器上發現問題。
- 正在為缺席的粉絲直播下列活動:
%PLATFORM-1-PFM_ALERT: FAN_BAD: fan2 fan4
- 的輸出
#show environment描繪了相關風扇缺席且沒有故障。
Fan: ----------------------------------------------------------------------------------------------------------------- Fan Model Hw Status Airflow direction Fan Speed[Fan0-Fan1] (rpm) ----------------------------------------------------------------------------------------------------------------- ChassisFan1 FAN Module 1 -- Ok Back to Front 7142 - 5258 ChassisFan2 ---------- -- Absent NA NA ChassisFan3 FAN Module 3 -- Ok Back to Front 7161 - 5263 ChassisFan4 ---------- -- Absent NA NA Fan_in_PS1 -- -- Ok Back to Front -- Fan_in_PS2 -- -- Absent NA -- Fan Air Filter : NotSupported
Cause
Cisco 問題:CSCvm02193(需要登入 Cisco 網站)
Resolution
沒有因應措施,因為這是外觀錯誤,但這是常見問題。
確認風扇是否實際存在或不存在。如果缺少風扇,請將交換器升級至 8.3(2),這可修正此問題。
Additional Information
Cisco 問題 CSCvm02193 列在 「Cisco MDS NX-OS Release 8.3(2) 的已解決注意事項」下方。
版本資訊 8.X 的副本隨附於 KB 以供參考。
版本資訊 8.X 的副本隨附於 KB 以供參考。
Affected Products
Connectrix MDS-9132TArticle Properties
Article Number: 000188724
Article Type: Solution
Last Modified: 18 Jul 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.