PowerVault ME5: Fejlfinding af iSCSI-controllerens EthernetPort Link Negotiation eller Link Down

Summary: Denne artikel hjælper med isolering af fejl, når et Ethernet-portlink ikke fremkommer, eller porten ikke forhandler den forventede linkhastighed med PowerVault ME5 iSCSI-controllermoduler. ...

This article may have been automatically translated. If you have any feedback regarding its quality, please let us know using the form at the bottom of this page.

Article Content


Instructions

 

Tjekliste, når et portlink til controllermodulet er nede

Generelle anbefalinger

  • Der er ingen leverandørlåse til kabler eller transceivere, der bruges til at forbinde PowerVault ME5-controllermoduler. Dell validerer kabler og transceivere til brug sammen med PowerVault ME5.
  • Ethernet-switchens firmware skal være opdateret, og de anvendte porte skal være aktiveret (dvs. ingen nedlukninger) og konfigureres ved hjælp af switchens kommandolinjegrænseflade eller switchens grafiske administrationsgrænseflade, hvor det er relevant. Se dokumentationen til switchleverandøren for specifikke konfigurationskommandoer.
  • Ethernet-switchleverandører kan angive transceivere, kabeltyper og kabellængder, der understøttes sammen med deres udstyr.
    • Alle komponenter (NIC'er, switch-porte, transceivere, kabler) skal klassificeres for at understøtte den forventede forbindelseshastighed. En SFP+ transceiver aftaler f.eks. kun 10 GB forbindelseshastighed. Et kabel, der er for langt eller ikke er konstrueret til specifikationerne, opfylder muligvis ikke kravene til indsætningstab (dB) for at danne et pålideligt link. Et værts-NIC, der er designet til at fungere ved 10 GB, opretter ikke et link ved 25 GB.
  • Værtsoperativsystemer skal have NIC-enhedsdriveren indlæst og porten konfigureret i operativsystemet.
  • Enhedsdriveren og firmwaren til NIC (Host Operating System Network Interface Cards) skal begge have minimumversioner eller nyere som anbefalet af udstyr eller operativsystemleverandør.
  • Porte bør automatisk forhandle forbindelseshastighed, i de fleste tilfælde er faste portindstillinger unødvendige og kan forhindre pålidelig linkkommunikation.

Lokal inspektion

  • Er alle enheder tændt, og operativsystemer er fuldt startet op?
  • Er kabler eller transceivere og fiberoptiske kabler tilsluttet korrekt på begge sider af forbindelsen?
  • Er kablerne i god tilstand? Administration af rackkabel skal være pænt, og kabler må ikke være sløjfede, strækbare eller beskadigede.
  • Forbindelseshastigheden og status-LED'erne skal observeres under og efter indsættelse af kablerne i begge ender af forbindelsen.
    • For PowerVault ME5-controllermoduler skal du se statusafsnittet for LED-status for controllermodul længere nede.
    • For Ethernet-switch-porte eller værts-NIC-porte henvises til leverandørdokumentationen for oplysninger om port-LED-status.
    • Se dokumentationen til værtsoperativsystemet for at konfigurere IP-adresser på Ethernet-porte.
  • Hvis linket er aktiveret, skal du bruge ping kommandoen fra værtsoperativsystemet til at teste IP-netværksforbindelsen mellem værten og PowerVault ME5-portene.
  • Direkte værtsforbindelse:
    • Enhedsdrivere til værtsoperativsystemets netværkskort skal være installeret, og netværksporten skal være konfigureret i operativsystemet.
    • Brug brugergrænsefladen for operativsystemet til at konfigurere og foretage fejlfinding af porte. Til reference er her også nogle kommandoer, der kan være nyttige.
  • Understøtter værts-NIC-modellen de forventede forbindelseshastigheder?
  • Kontroller, at værtens NIC-enhedsdriver og NIC-firmware er opdateret. Dell PowerEdge-servere og understøttede NIC-drivere og -firmware er ofte tilgængelige på Dell Support.
  • Hvor det er relevant, brug netværkskortadministrationsværktøjer, der følger med NIC-driversoftware, til at overvåge linket, portindstillinger og statistik, f.eks. Intel PROset eller Marvell QConvergeConsole
  • Undersøge værtsoperativsystemets hændelseslogfiler eller kernelogfiler for meddelelser vedrørende linkstatus eller enhedsdriver til netværksgrænsefladen.
Nyttige kommandoer til at hente værts-NIC-indstillinger:
 
Operativsystem Kommando Beskrivelse
VMware ESXi esxcli-netværks-nic-liste Vis netværksadaptere
esxcli network ip interface list Vis oplysninger om vmk-netværkskort.
esxcli network ip interface ipv4 get Angiv IP-adressen.
Linux lspci
lshw
lspci til at angive alle PCI-enheder
lshw for at identificere Ethernet-grænseflader og NIC-hardware
ethtool Se NIC eller kortdriver og indstillinger på Linux.
ip addr Angiv den IP-adresse, der skal tildeles NIC-grænseflader.
Microsoft
Windows Server
Powershell:
Get-PnpDevice -PresentOnly | select-string "ethernet","network"
Vis alle enheder, der filtrerer for Ethernet og netværk.
Powershell:
Get-IntelNetAdapter
Vis Intel-netværksadaptere, når Intel NIC-enhedsdriversoftwaren er installeret.
ipconfig/all
Eller
PowerShell: 
Get-NetIPAddress -AddressFamily IPv4
Angiv IP-adressen.
  • Ethernet-switchforbindelser:
    • Undersøg switchens kørende konfiguration. Tilsluttede porte skal være aktiveret på switchen, dvs. ingen nedlukning
    • Undersøge switchens hændelseslogfiler for portlink-up- eller down-hændelser.
    • Undersøge switch-portens grænsefladestatistik for portfejl som f.eks. overdrevne CRU'er, tab osv., der tyder på et problem med kabelføring eller transceivere.
    • Undersøg switch-portgrænsefladen for tilknyttede medieoplysninger.

I afsnittet Ethernet-switch-specifikationsanbefalinger for iSCSI-trafik vises switchfunktioner, der anbefales for optimal ydeevne ved brug af iSCSI-protokollen.

 

Forbindelseshastigheder og -kabler, der understøttes efter controllertype

Controllertype
Forbindelsesgrænseflade
1 GB 10 GB 25 GB Kabel
10 Gb iSCSI Base-T RJ45 Ja Ja Nej RJ45 CAT-6- kobberforlændingsledning
25 GB iSCSI SFP+ Nej Ja Nej SFP+ transceiver – eller - DAC-kabel (SFP+ Direct Attach Kobber)
25 GB iSCSI SFP28 Nej Ja Ja SFP28-transceiver - eller - SFP28 DaC-kabel (Direct Attach Kobber)
 
  • CAT 5/e-kabel er godkendt til 1000base-T-forbindelser
  • Brug CAT 6 eller bedre kabel til 10Gbase-T-forbindelser.
  • Brugen af daC-kablet (passive direct attach kobber) op til maks. 5 meter understøttes. Ingen aktive kobberkabler eller aktive optiske kabler understøttes.
  • Nogle Ethernet-switch-leverandører understøtter muligvis kun kortere DAC-kabellængder. For kabelanbefalinger skal du følge dokumentationen fra switch-leverandørerne.
  • Dell hverken anbefaler eller validerer brugen af DAC-breakout-kabler med PowerVault ME5.
  • Hvis du vælger at bruge DAC-breakout-kabler, skal du bruge de kortest mulige længder, så de længste kabler fungerer muligvis ikke altid pålideligt i dit miljø.
  • Til fiberoptikkabel skal du bruge kabler med OM3- eller OM4-fiberfiber (MMF). De maksimalt understøttede afstande varierer afhængigt af transceiver, forbindelseshastighed og kabelkvalitet.
  • Langrækkevidetransceivere (LR), der bruges sammen med fiberoptikkabel med enkelttilstand, fungerer muligvis, men Dell har ikke valideret brugen med PowerVault ME5.
 

LED-status for controllermodul

Statusvejledningen til controllermodulet kan findes i brugervejledningen til PowerVault ME5-seriens storagesystem i afsnittet LED-indikatorer for controllermodul
 

BEMÆRK: Leverandører af switche og værts-NIC'er bruger også LED'er til at angive linkhastighed og aktivitetsstatus for at få flere oplysninger i enhedsproduktdokumentationen.
 
25 GB iSCSI-controllerport-LED'er
LED-indikator BESKRIVELSE FARVE STATUS
image.png iSCSI 25 Gb/10 Gb linkaktivitet Grøn Til – Tilsluttet, linket er aktiveret
Blinker – linkaktivitet
Slukket – Ikke tilsluttet, eller forbindelsen er nede

Figur 1: 25 GB iSCSI-controllerportens LED'er

 
10 GB iSCSI Base-T-port-LED'er
LED-indikator BESKRIVELSE FARVE STATUS
image.png iSCSI 10Gbase-T-forbindelseshastighed Grøn Til – 10 GbE-forbindelseshastighed
Amber Til – 1 GbE-forbindelseshastighed
Ingen Slukket – Ikke tilsluttet, eller forbindelsen er nede
HANDLE iSCSI 10Gbase-T-forbindelsesaktivitet Grøn Til – Tilsluttet, linket er aktiveret
Blinker – linkaktivitet
Slukket – Ikke tilsluttet, eller forbindelsen er nede

Figur 2: 10 GB iSCSI Base-T Port-LED'er
 

Se portstatus ved hjælp af PowerVault Manager


1: Hardwarepanelet (Maintenance > Hardware) viser systemets hardwarekonfiguration.

2: Klik på fanen Set bagfra.

3: Klik på hver enkelt port igen for at få vist specifikke oplysninger om hver port. Rul ned for at se hver portlinkstatus, linkhastighed og oplysninger om tilsluttede medier, hvor det er relevant.

Vælg Set bagfra, og klik derefter på hver enkelt port for at se den aktuelle portstatus
Figur 3: Vælg Set bagfra, og klik derefter på hver enkelt port for at se den aktuelle portstatus.
 
Der vises oplysninger om den markerede port

Figur 4: Der vises oplysninger om en bestemt port.
 

  • Handlinger, Nulstil værtsport bør kun bruges som et fejlfindingstrin, når der ikke er noget link, og kablet er tilsluttet.
 

Få vist portstatus ved hjælp af PowerVault Command Line Interface

  1. Åbn en SSH-session til begge controlleres IP-administrationsadresse ved hjælp af et terminalprogram som f.eks. PuTTYDette hyperlink fører dig til et websted uden for Dell Technologies..
  2. Kør følgende kommandoer:
Kommando Beskrivelse
show system Kontrollér, at systemets tilstand er OK, og at begge controllermoduler (hvor det er relevant) vises.
show alerts unresolved Uløste advarsler kan hjælpe med at forklare de symptomer, der opleves.
show ports detail Angiv controllermodulets portlinkstatus og oplysninger om tilsluttede medier.
show host-port-statistics Se portstatistik for at afgøre, om I/O går gennem porten.
 
BEMÆRK: Følgende kommandooutput afkortes for at vise outputtet fra én port.
 
# show ports
Ports Media  Target ID                                   Status        Speed(A) Health     Reason Action
---------------------------------------------------------------------------------------------------------
A0    iSCSI  iqn.1988-11.com.dell:01.array.xxxxxxxxxxxx  Up            10Gb     OK

   Port Details
   ------------
   IP Version: IPv4
   IP Address: 192.168.200.220
   Gateway: 0.0.0.0
   Netmask: 255.255.255.0
   MAC: 00:xx:xx:xx:xx:xx



# show ports detail
Ports Media  Target ID                                   Status        Speed(A) Health     Reason Action
---------------------------------------------------------------------------------------------------------
A0    iSCSI  iqn.1988-11.com.dell:01.array.xxxxxxxxxxxx  Up            10Gb     OK

   Port Details
   ------------
   IP Version: IPv4
   IP Address: 192.168.200.220
   Gateway: 0.0.0.0
   Netmask: 255.255.255.0
   MAC: 00:xx:xx:xx:xx:xx
   SFP Status: OK
   Part Number: D0R73
   10G Compliance: Special
   Ethernet Compliance: N/A
   Cable Technology: Passive
   Cable Length: 2


For at afgøre, om iSCSI-trafikken passerer på portene, skal du bruge kommandoen:show host-port-statistics

# show host-port-statistics
Durable ID           Bps                IOPS             Reads            Writes           Data Read        Data Written     Queue Depth      I/O Resp Time    Read Resp Time   Write Resp Time  Reset Time
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
hostport_A0          0B                 0                154              244              3677.6KB         48.5MB           0                0                0                0                2022-06-24 17:43:15
hostport_A1          0B                 0                151              245              3403.2KB         48.5MB           0                0                0                0                2022-06-24 17:43:15
hostport_A2          0B                 0                0                0                0B               0B               0                0                0                0                2022-06-24 17:43:15
hostport_A3          0B                 0                0                0                0B               0B               0                0                0                0                2022-06-24 17:43:15
hostport_B0          0B                 0                9                0                12.2KB           0B               0                0                0                0                2022-06-24 17:43:31
hostport_B1          0B                 0                9                0                12.2KB           0B               0                0                0                0                2022-06-24 17:43:31
hostport_B2          0B                 0                0                0                0B               0B               0                0                0                0                2022-06-24 17:43:31
hostport_B3          0B                 0                0                0                0B               0B               0                0                0                0                2022-06-24 17:43:31
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Success: Command completed successfully. (2022-07-03 21:26:52)

 

Ethernet-overvejelser på 25 GB

25 GB Ethernet introducerer nye overvejelser, der ikke findes ved fejlfinding af Ethernet-forbindelseshastigheder på 10 GB og 1 GB.

  • 25 Gb standard IEEE 802.3by blev godkendt i juni 2016. Komponenter skal overholde denne standard for at kunne fungere pålideligt på 25 GB.
  • SFP28 transceiver-formfaktoren er plug-kompatibel med SFP+-netværksporte, og de fleste SFP28-transceivere afstemmer forbindelseshastigheder på 10 Gb.
  • På stedet kan der være en blanding af 10 GB og 25 GB transceivere og kabler. Disse er plug-kompatible og ser ens ud. Undersøg derfor etiketterne og varenumrene på transceivere eller kabler, der bruges til at sikre, at de er klassificeret til 25 GB. Udvalget af Dell-leverede varenumre sammen med modeller er angivet i PowerVault ME5-supportmatrixen under afsnittene iSCSI-transceivere og understøttede kabler.
Dell-varenummer vist i kabelpakning
Figur 5: Dell-varenummer vist i kabelemballage


Dell-varenummer og model vist på transceiver-emballageFigur 6: Dell-varenummer og -model vist på transceiver-emballage


Dell-varenummers placering på DAC-kabel, figur 7: Dell-artikelnummers placering på DAC-kabel


Dell-leverede SFP28-transceiver viser varenummer, model og PPIDFigur 8: Dells leverede SFP28-transceiver viser varenummer, model og PPID.
 

Fejlisolering

Der er ingen Ethernet-forbindelse mellem PowerVault ME5-controllerporten og enten switch-porten eller værts-NIC-porten.

Tilslut kablerne eller transceiverne til de samme enheder for at kontrollere, om der vises et link. Du behøver ikke et krydskabel på 1 GB, 10 GB og 25 Gb porte, der understøtter AutoMDI-X.

1. Tilslut transceiver- og fiberoptikkablet eller DAC-kablet ved hjælp af en ledig port på controller A til en anden ledig port på controller B (for eksempel tilslut controller A-port 0 til controller B-port 0).

  • Hvis linket fremkommer, skal du kontrollere, hvilken hastighed det forhandler med. Dette kan være en nyttig måde at kontrollere kabel- eller fiberoptiktransceiverens understøttede forbindelseshastighed på.
  • Hvis forbindelsen ikke tænder, kan du bytte testen med et andet kabel, en transceiver eller en anden portkombination.
BEMÆRK: Vær opmærksom på potentiel kontamination af stikkene, når du bruger fiberoptikkabel og transceivere. En kombination af støv, olie, sved eller ridser i enderne af stik kan forårsage refragmentering af lyset uden forbindelse eller et signal af dårlig kvalitet, der forårsager dårlig ydeevne under belastning.

2. Når du bruger en Ethernet-switch-test, skal du bruge den samme metode ved at tilslutte kablet fra den ene port til den anden på den samme switch. Hvis der ikke er noget link, skal du følge vejledningen til fejlfinding for switch-leverandører.

3. Hvis du bruger en direkte værtsforbindelse mellem ME5-controllermodulporten og værtsporten, skal du tilslutte kablet fra den ene port til den anden på den samme værts-NIC, hvis grænsefladekortet har to eller flere porte. Hvis der ikke er et link, skal du sørge for, at operativsystemets enhedsdriver er indlæst, og at portene ikke er deaktiveret i værtsoperativsystemet.

Hvis dette ikke er muligt at fastslå kilden til problemet, skal du kontakte din netværksadministrator, eller Dell ProSupport-kunder kan også kontakte Dells tekniske support for at hjælpe med fejlfinding Se kontakt til Dells tekniske support for at få yderligere hjælp nedenfor.

Anbefalinger til Ethernet-switchspecifikationer for iSCSI-trafik

Der er mange Ethernet-switch-leverandører på markedet. Dell har ikke en kompatibilitetsliste over Ethernet-switche, der understøtter iSCSI-trafik med PowerVault ME5.

Generelle krav til switche til understøttelse af iSCSI-trafik.

  • Alle switch-komponenter i SAN'et skal have aktive supportkontrakter med enhedsleverandøren.
  • Flowstyring af linkniveau (IEEE 802.3x) på indgangsporte eller indgående switchporte (også kendt som "Rx Flowstyring" eller "modtageside-flowstyring" fra switch-portens visning)
  • Dynamisk pakkebufferhåndtering med minimum:
    • 4 MB delt pakkebuffer til 1 Gbps-switche
    • 9 MB delt pakkebuffer til 10 Gbps-switche
    • 32 MB delt pakkebuffer til 25 Gbps-switche
  • Mulighed for at konfigurere porte til øjeblikkelig videresendelsestilstand for Edge-porte (muligvis kendt som "portfast"-tilstand)
  • Understøttelse af Jumbo Frames (MTU 9000+ bytes) hvis aktiveret på PowerVault ME5

PowerVault ME-switchkonfigurationer ligner SC-seriens systemer. Hvis du skal søge referencekonfigurationsmateriale for at konfigurere en switch til iSCSI, henvises til Dell-artiklen 124943: Skift konfigurationsvejledninger for SC-seriens eller PS-seriens SAN'er.

Replikering på PowerVault ME kræver en switch.
Begge PowerVault ME-systemer skal være tilsluttet samme struktur eller netværk ved hjælp af en switch. direkte forbindelse mellem storagesystemer understøttes ikke. Reference: Implementeringsvejledning – Kabelføring til replikering (PDF)

Kontakt Dells tekniske support for hjælp til fejlfinding

Dells tekniske support kan bede dig om at give nogle eller alle følgende oplysninger afhængigt af problemets omfang.

1. Supportbundt fra PowerVault ME5. (påkrævet)
Instruktioner til at indsamle eller sende supportlogfiler til PowerVault ME5 findes i Dell-artiklen 196715: ME5: Sådan indsamler du supportlogfiler

til PowerVault2. Oplysninger om de anvendte kabler eller transceivere (påkrævet)
til DAC Twinax-kabler. Dells tekniske support ønsker at kende kabelleverandøren, varenummer og længde.

Til transceivere skal der være et foto af SFP+ eller SFP28 transceiver-mærkaten, der viser delnumre og modeller, der anvendes i hver ende af forbindelsen.

Dell-leverede SFP28-transceiver viser varenummer, model og PPID (2).
Figur 9: Dell-leverede SFP28-transceiver viser varenummer, model og PPID (2).
 

3. Oplysninger eller logfiler fra den tilsluttede Ethernet-switch, der bruges til iSCSI-trafik (hvor ønsket)

Generelt ønsker Dells tekniske support at kende switchmodellen, switchfirmware, porte, der bruges på Ethernet-switchen, som er tilsluttet PowerVault ME5, medielager og fejlstatistik for porte med tilsluttede medier og switchhændelseslogfiler, der kan indikere eventuelle problemer, f.eks. spanning tree loops eller indsættelse af medie- og linkregistreringsstatus, og vigtigt, om er den anvendte switch-port aktiveret.

For de fleste switchmodeller kan administratorer åbne en SSH-session ved hjælp af et terminalprogram som f.eks. PuTTYDette hyperlink fører dig til et websted uden for Dell Technologies. og hente outputtet fra de kommandoer, der er anført nedenfor, til tekstfilen.

Syntaksen i følgende kommandoer varierer afhængigt af switchens leverandør og model. Se leverandørens dokumentation for at finde den tilsvarende kommandosyntaks for din Ethernet-switchmodel.    

Dell PowerSwitch CISCO Catalyst Beskrivelse
show tech-support | no-more term len 0
show tech-support
Denne kommando er en samling af flere diagnosticeringskommandoer, der bruges af teknisk support til at undersøge switchkonfiguration og porttilstand.
show inventory media | no-more term len 0
show interfaces transceiver
show interfaces transceiver detail
Viser oplysninger om transceivere, der har aktiveret digital optisk overvågning (DOM)
show lldp neighbors | no-more show lldp neighbors Vis LLDP-naboinformation for alle grænseflader eller en bestemt grænseflade. Funktionen er muligvis ikke aktiveret på al switch-firmware.
show mac-address-table | no-more show mac address-table Bruges til at afgøre, om en slutenheds MAC-adresse læres på en switch.


4. Oplysninger eller logfiler fra et tilsluttet værtsoperativsystem (hvor ønsket)

Generelt ønsker Dells tekniske support at kende oplysninger om det anvendte netværkskort (NIC), enhedsdriveren og firmwaren, der anvendes af NIC- og OS-portkonfigurationen.

Det kan være nødvendigt at gennemgå hændelseslogfiler og konfigurationer for værtsoperativsystemet yderligere for at afgøre, om anbefalede bedste konfigurationspraksisser er blevet fulgt. Du kan også finde oplysninger om best practice på Dell Technologies Informationshub.

Følgende hjælpeprogrammer kan gøre det nemmere at indsamle logfiler for operativsystemet. Adgang på administratorniveau er påkrævet for at køre værktøjer til indsamling af logfiler.
 

Operativsystem Hjælpeprogram Beskrivelse
VMware ESXi vm-support Indsamler ESXi-værtsdiagnosticeringslogfiler, se VMware-artiklen "vm-support"-kommandoen i ESX/ESXi for at indsamle diagnosticeringsoplysninger Dette hyperlink fører dig til et websted uden for Dell Technologies.
Linux sosreport De fleste Linux-distributioner omfatter sosreport-hjælpeprogrammet. Se Red Hat-artiklen Hvad er en sos-rapport, og hvordan opretter man en i Red Hat Enterprise Linux? Dette hyperlink fører dig til et websted uden for Dell Technologies.
Windows Server emcgrab Dell-artikel 69288: Sådan køres EMC Grab på Microsoft Windows-værter.


BEMÆRK: Nogle af disse logfiler er større, end der kan sendes via e-mail. Dells tekniske supportmedarbejder kan bede dig om at uploade logfilerne ved hjælp af Dell-filoverførsel , eller de kan give en SFTP-forbindelse med adgangsoplysninger.
 
 

Article Properties


Affected Product

ME Series, Dell EMC PowerVault ME412 Expansion, Dell EMC PowerVault ME424 Expansion, Dell EMC PowerVault ME484, PowerVault ME5012, PowerVault ME5024, PowerVault ME5084

Last Published Date

31 Aug 2023

Version

10

Article Type