Los nodos de PowerScale pasan a solo lectura después de la actualización de OneFS 9.1
Summary: Después de actualizar un clúster a OneFS 9.1.0.20, todos los nodos de PowerScale (F200, F600, F900) del clúster pasan al modo de solo lectura.
Symptoms
Node Pool Name: f600_60tb-ssd_384gb Protection: +2d:1n Pool Storage: HDD SSD Storage Size: 0 (0 Raw) 0 (0 Raw) VHS Size: 0.0 Used: 0 (n/a) 0 (n/a) Avail: 0 (n/a) 0 (n/a) Throughput (bps) HDD Storage SSD Storage Name Health| In Out Total| Used / Size |Used / Size -------------------+-----+-----+-----+-----+-----------------+----------------- 123|n/a |-A-R |938.7| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 124|n/a |-A-R | 0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 125|n/a |-A-R | 0|10.8M|10.8M|(No Storage HDDs)|(No Storage SSDs) 126|n/a |-A-R | 0| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 127|n/a |-A-R | 1.4k| 9.9M| 9.9M|(No Storage HDDs)|(No Storage SSDs) 128|n/a |-A-R | 0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs) 129|n/a |-A-R | 0| 7.9M| 7.9M|(No Storage HDDs)|(No Storage SSDs) 130|n/a |-A-R | 0| 7.3M| 7.3M|(No Storage HDDs)|(No Storage SSDs) -------------------+-----+-----+-----+-----+-----------------+----------------- f600_60tb-ssd_384gb| OK |293.3| 9.2M| 9.2M|(No Storage HDDs)|(No Storage SSDs)
Verá entradas similares a las siguientes en el archivo /var/log/messages para los nodos afectados:
2022-07-26T01:40:46+02:00 (id92) isi_testjournal: NVDIMM is persistent 2022-07-26T01:40:46+02:00 (id92) isi_testjournal: NVDIMM armed for persistent writes 2022-07-26T01:40:47+02:00 (id92) ifconfig: Configure: /sbin/ifconfig ue0 netmask 255.255.255.0 169.254.0.40 2022-07-26T01:40:47+02:00 (id92) dsm_ism_srvmgrd[2056]: ISM0000 [iSM@674.10892.2 EventID="8716" EventCategory="Audit" EventSeverity="info" IsPastEvent="false" language="en-US"] The iDRAC Service Module is started on the operating system (OS) of server. 2022-07-26T01:40:47+02:00 (id92) dsm_ism_srvmgrd[2056]: ISM0003 [iSM@674.10892.2 EventID="8196" EventCategory="Audit" EventSeverity="error" IsPastEvent="false" language="en-US"] The iDRAC Service Module is unable to discover iDRAC from the operating system of the server. 2022-07-26T01:44:15+02:00 (id92) isi_testjournal: PowerTools Agent Query Exception: Timeout (20 sec) exceeded for request http://127.0.0.1:8086/api/PT/v1/host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor data: HTTPConnectionPool(host='127.0.0.1', port=8086): Read timed out. (read timeout=20) 2022-07-26T01:44:20+02:00 (id92) isi_testjournal: Query to PowerTools Agent for NVDIMM Battery failed
Cause
Resolution
Para verificar que el NVDIMM esté en buen estado y que se esté ejecutando en el problema descrito en este artículo de la base de conocimientos, ejecute los siguientes cuatro comandos:
# isi_hwmon -b NVDIMMHealthMonitoring # isi_hwmon -b NVDIMMPersistence # /opt/dell/DellPTAgent/tools/pta_call get agent/info # /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Estos comandos son solo comandos de consulta y se deben considerar no disruptivos.
La salida de los comandos para un nodo en este estado debe ser similar a la siguiente:
# isi_hwmon -b NVDIMMHealthMonitoring
DIMM SLOT A7: OK
# isi_hwmon -b NVDIMMPersistence
NVDIMM Index 0
State: PERSISTENT
Vendor Serial ID: xxxxxxxxx
Correctable ECC Count: 0
Uncorrectable ECC Count: 0
Current Temp: 255
Health: 0
NVM Lifetime: 90
Warning Threshold Status: 0
Error Threshold Status: 0
Health Info Status: 0
Critical Health Info: 0
Critical Info Status: 0
Last Save Status: 0
Last Restore Status: 0
Last Flush Status: 0
Armed: 1
SMART/Health Events Observed: 0
FW Health Monitoring: 1
NVDIMM Mapped: 1
# /opt/dell/DellPTAgent/tools/pta_call post "host/sensordata?sensorSelector=iDRAC.Embedded.1%23SystemBoardNVDIMMBattery&sensorType=DellSensor"
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
"HealthState": "OK",
"EnabledState": "Enabled",
"ElementName": "System Board NVDIMM Battery",
"SensorType": "Other",
"Id": "iDRAC.Embedded.1_0x23_SystemBoardNVDIMMBattery",
"CurrentState": "Good"
}
Response: status: 200 [OK], size: 223 bytes, latency: 0.034 seconds.
# /opt/dell/DellPTAgent/tools/pta_call get agent/info
Request sent to DellPTAgent @ http://127.0.0.1:8086 [127.0.0.1]
{
"idrac_ethernet_ip": "0.0.0.0",
"servicetag": "xxxxx",
"uptime": "2511 seconds ( 41 minutes 51 seconds )",
"status": {
"agent": "OK",
"idracConnection": "OK",
"idraccache": "OK",
"iSM": "N/A"
},
"name": "ClusterName-123",
"MarvellLibraryVersion": "Not loaded",
"system_uuid": "xxxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx",
"default_server_cert": "true",
"rest_endpoints": "http://127.0.0.1:8086"" [127.0.0.1],
"ptagentversion": "2.5.6-4",
"domain": "",
"host_epoch_time": "xxxxxxxxxx.354221 (secs.usecs)",
"os_version": "9.1.0.0",
"mfr": "Dell Inc.",
"process_id": "2071",
"api_blocking_enabled": "false",
"host_pass_thru_ip": "xxx.xxx.xxx.xxx",
"model": "PowerScale F600",
"idrac_pass_thru_ip": "xxx.xxx.xxx.xxx",
"os": "Isilon OneFS",
"ism_version": "dell-dcism-3.4.6.13_7"
}
Response: status: 200 [OK], size: 871 bytes, latency: 0.009 seconds.
El resultado dado aquí es un ejemplo y puede haber variaciones en la salida que obtiene. La parte importante es que la salida se ve similar y que no aparece un mensaje de error en lugar de la salida.
- Si hay algún indicio de problemas o errores de comunicaciones, debe continuar con la solución del problema e involucrar a un L2/SME de hardware o al equipo de soporte de PowerEdge según sea necesario.
- Si la salida indica que el NVDIMM está en buen estado y no hay problemas, puede borrar manualmente el estado de RO mediante el siguiente comando:
# /usr/bin/isi_hwtools/isi_read_only --unset=system-nvdimm-failed
Una vez que haya aplicado el paso correctivo, monitoree el nodo durante aproximadamente 10 minutos para asegurarse de que no vuelva al modo de RO. Si se realiza un ciclo de apagado y encendido del nodo o se reinicia, este problema puede ocurrir nuevamente y es posible que deba volver a aplicar esta solución alternativa. El equipo de ingeniería de PowerScale está al tanto de este problema y está investigando los pasos de mitigación que se implementarán en una próxima versión de OneFS 9.1. Mientras tanto, para resolver permanentemente este problema, puede actualizar el clúster a OneFS 9.2 o a una versión más reciente.