Dell VxRail 上的 VCF:VI-WLD 叢集新增失敗,並顯示錯誤「執行 dvs 相關驗證」
Summary: VxRail 工作負載網域叢集 Add for VI-WLD 上的 VCF 失敗,並出現錯誤「執行 dvs 相關驗證。vxrail 4.4.1.1 與 VxRail 7.0.371 上的 vcf 主機 hostxx.abc.xyz 規格中傳遞的 vmnic 不相容。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
在「Workload domain Cluster Add for VI-WLD」期間,使用者可能會在 SDDC Manager 的工作窗格中看到以下錯誤:
Description: Perform dvs related validations. Failed Error: Incompatible vmnic passed in host hostxx.abc.com specification

Domainmanager.log:
2023-02-03T14:19:05.021+0000 INFO [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.c.c.v.vsphere.VcManagerBase,dm-exec-5] In total 5 vmnics are in-use: ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] In Use Pnics ["vusb0","vmnic3","vmnic7","vmnic2","vmnic5"]
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic0
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.021+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic1
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic2
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic3
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic4
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic5
2023-02-03T14:19:05.022+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic6
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed null
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vmnic7
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":25000,"duplex":true}
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Translating for vusb0
2023-02-03T14:19:05.023+0000 DEBUG [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.v.v.p.service.NICServicePlugin,dm-exec-5] Link speed {"speedMb":100,"duplex":true}
2023-02-03T14:19:05.036+0000 ERROR [vcf_dm,cf4d3c3d17f10a83,bd58] [c.v.e.s.o.model.error.ErrorFactory,dm-exec-5] [46IH24] VSPHERE_INCOMPATIBLE_VMNIC_SPEC_FAILED Incompatible vmnic vmnic6 passed in host vh01-abc.xyz specification
Cause
新增叢集中其中一個主機上的 NIC 狀態不佳,會導致此錯誤。
可能是實體 NIC 已關閉,或 NIC 的連結速度與主機上的其他 NIC 不相符。
Resolution
要解決此問題:
從 domainmanager 記錄檔中識別已報告的主機和實體 NIC。
檢查實體 NIC 狀態和連結速度。如果埠已關閉或連結速度不正確,請逐一執行下列步驟,直到問題解決:
- 嘗試重新插接網路纜線。
- 驗證交換器埠組態。
- 將網路纜線換成已知良好的纜線。
- 重新啟動主機,並檢查 vmnic 狀態。
實體 NIC 狀態良好後: