PowerStore: Metro devices report target port group with zero target port count on Linux hosts

Summary: Target Port Group (TPG) values and information are incorrect on PowerStore Metro volumes on a Linux system for PowerStoreOS versions 3.x.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Target Port Group (TPG) values and information are incorrect on PowerStore Metro volumes on a Linux system for PS-OS versions 3.x.
 

 

Cause

The nonauthoritative TPG information (essentially the remote TPG data), for the PowerStore Metro ports are not reported correctly from PowerStore.
ESXi always accepts the authoritative information about a path, i.e. the information that comes back on path1 about path1 is authoritative. Arrays are also required to report information about paths they do not own. These are called nonauthoritative paths. PowerStore remote nonauthoritative paths return incorrect information about the TPGs.

 

 

Resolution

Metro protection in PowerStoreOS versions 3.x supports FC/SCSI or iSCSI connected VMware ESXi hosts.

For more information, see "Dell EMC PowerStore Release Notes" and "Dell EMC PowerStore Protecting Your Data" documents for appropriate version. 

 

Affected Products

PowerStore
Article Properties
Article Number: 000212670
Article Type: Solution
Last Modified: 13 Jun 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.