Data Domain: NetBackup 8.1 on Solaris reports error status 84 (media write error)

Summary: Data Domain: This article describes that NetBackup 8.1 on Solaris may report with backup error status 84 (media write error).

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

When running backup jobs on DDVTL LTO-7 drives using NetBackup on Solaris, it fails with the following error.

Error bptm (pid=53194) FREEZING media id 0006L7, too many data blocks written, check tape/driver block size configuration
Info bptm (pid=53194) EXITING with status 84


These error messages are found in the NetBackup log bundle.

Cause

The larger I/O operations are split at the driver layer due to st (tape driver) driver config settings.

For a few I/O operations, one NetBackup write resulted into two split blocks writes on DDVTL. Therefore, a mismatch was seen in the block count.

vtcck outputs show that one record of 65536 was split into two records. That is, one record sized 65534 bytes and another sized 2 bytes.

We see that there are two byte-sized records which were created for few of the operations.
 
21 data and 11 filemark records processed
Minimum record size: 2
Maximum record size: 65534
Average record size: 16140
Record Size    Number of Records
         2    1
       1024    11
      32768    8
      65534    1
      good: YES

Resolution

The workaround is to edit the "st.conf" and reboot.

1. Run the Solaris command # mt config on the DDVTL LTO-7 tape drive.
For example, # mt -f /dev/rmt/0 config

The following result (with the fourth parameter being 0x1065B) indicates that the problem exists.  
tape-config-list =
        "IBM     ULTRIUM-TD7", "IBM     ULTRIUM-TD7", "CFGIBMULTRIUMTD7";
        CFGIBMULTRIUMTD7 = 2,0x3B,0,0x1065B,4,0x00,0x00,0x00,0x00,0,120,120,3600,3600,3600,3600,3600;

2. Edit the Solaris file /kernel/drv/st.conf to include the ST_NO_RECSIZE_LIMIT (0x8000) flag in the "tape-config-list." 
tape-config-list =
        "IBM     ULTRIUM-TD7", "IBM     ULTRIUM-TD7", "CFGIBMULTRIUMTD7";
        CFGIBMULTRIUMTD7 = 2,0x3B,0,0x1865B,4,0x00,0x00,0x00,0x00,0,120,120,3600,3600,3600,3600,3600;
3. Reboot with reconfigure option.
# reboot -- -r

Affected Products

Data Domain
Article Properties
Article Number: 000213846
Article Type: Solution
Last Modified: 15 Sep 2023
Version:  2