Connectrix:B系列:執行 configdownload 命令時,發生組態檔案標頭無效的錯誤

Summary: 使用「configdownload」命令將備份的交換器組態載入至交換器時,便會出現此問題。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Error: Invalid header in config file

錯誤輸出 

Cause

此問題是由交換器橫幅的模式不同所導致。
在交換器更換過程中,舊交換器設定檔包含不同的交換器橫幅時,便會發生這種情況。新的交換器組態檔案有不同的模式,因此導致不相符。

Resolution

步驟 1:比較舊的交換器設定檔和新交換器設定檔,並注意橫幅中的差異。

第 2 步:例如:

舊交換器橫幅

============================================================= ATTENTION: It is recommended that you change the default passwords for all the switch accounts. Refer to the product release notes and the administrator's guide if you need further information. =============================================================

新交換器橫幅:
 -------------------------------------------------------------------------------------------- ATTENTION It is recommended that you change the default passwords for all the switch accounts. Refer to the product release notes and the administrator's guide if you need further information. --------------------------------------------------------------------------------------------

步驟 3:根據舊的交換器橫幅手動編輯新的交換器橫幅。

第 4 步:儲存組態檔案,並嘗試執行 configdownload
 