PowerProtect: VMware Instant Access -palautus ja FLR epäonnistuu Asennus epäonnistui

Summary: Virtuaalikoneen (VM) Instant Access (IA) tai tiedostotason palautus (FLR) epäonnistuu ja näyttöön tulee virhe "Mount failed: Sysinfo-toimintoa ei voi suorittaa"

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 

Instant Access Restore eli FLR epäonnistuu ja VM Direct Engine (VMDE) -asennuslokissa näkyy seuraava virhe.

Loki: mount-xxxxxxxxxx.log

Lokin sijainti: (Sulautettu VMDE) /opt/emc/vproxy/runtime/logs/recycle/vproxyd/ | /opt/emc/vproxy/runtime/logs/recycle/vbackupd/ (Ulkoinen VMDE)

YYYY-MM-DDThh:mm:ss.270Z NOTICE: [8d389cdc46ece06b;96ae9dbd0918a908] "Text": "Session '07fae483-61e9-43da-acca-b32f48656db0' is unsuccessful: Unable to create datastore: Unable to create datastore 'DELL-vProxy-ppdm01.fqdn 1682513359' using '*.*.*.*:/data/col1/Dev-Test-ppdm01-71b45/PLCTLP-XXXX/Restores/yyyy/zzzz-zzzz/1683583862592975399/1682025362/vProxy-ppdm01.fqdn xxxxxxx': ServerFaultCode: An error occurred during host configuration. Operation failed, diagnostics report: Mount failed: Unable to complete Sysinfo operation. Please see the VMkernel log file for more details.: Unable to query remote mount point's attributes",

Esimerkiksi PowerProtect Data Managerin versioissa 19.18 tai 19.19 ei luoda asennuslokia, ja alla oleva virhe voidaan havaita palautustyössä.

PowerProtect Data Manager -käyttöliittymä, jossa näkyvät epäonnistuneen työn tiedot

PowerProtect Data Managerin vmdm-loki sisältää seuraavan virhevirheen.

Loki: vmdm.log

Lokin sijainti: /var/log/brs/vmdm

2025-04-11T11:58:16.470Z WARN [] [request-dispatch-service-1] [][][][][] [c.e.b.v.r.c.StreamCountService.exchange(282)] - Exception Response Body {"code":500,"reason":"Cannot invoke \"com.emc.brs.datadomain.
ddboost.DdConnectionInfo.getConnDesc()\" because \"ddConnection\" is null","remediation":null,"timestamp":1744372696467,"path":"/api/v2/copies/a33f6343-85a8-4044-a992-dc4b8487d9fe/recovery-stream-counts","ex
tendedInfo":null}
2025-04-11T11:58:16.471Z ERROR [] [request-dispatch-service-1] [][][][][] [c.e.b.v.r.d.InstantAccessDispatchService.isRequestDispatchable(75)] - Exception checking allowance
com.emc.brs.vmdm.error.ComponentException: Cannot invoke "com.emc.brs.datadomain.ddboost.DdConnectionInfo.getConnDesc()" because "ddConnection" is null
        at com.emc.brs.vmdm.vpe.service.clients.RestClientBase.exchange(RestClientBase.java:284)
        at com.emc.brs.vmdm.vpe.service.clients.RestClientBase.get(RestClientBase.java:201)
        at com.emc.brs.vmdm.recovery.clients.StreamCountService.getStreamCounts(StreamCountService.java:51)
        at com.emc.brs.vmdm.recovery.dispatch.InstantAccessSessionService.exceedsAllowance(InstantAccessSessionService.java:90)
        at com.emc.brs.vmdm.recovery.dispatch.InstantAccessDispatchService.isRequestDispatchable(InstantAccessDispatchService.java:73)
        at com.emc.brs.vmdm.recovery.dispatch.InstantAccessDispatchService.isRequestDispatchable(InstantAccessDispatchService.java:31)
        at com.emc.brs.vmdm.recovery.dispatch.BaseRequestDispatchService.getRequestFromWaiting(BaseRequestDispatchService.java:301)
        at com.emc.brs.vmdm.recovery.dispatch.BaseRequestDispatchService.getRequest(BaseRequestDispatchService.java:232)
        at com.emc.brs.vmdm.recovery.dispatch.BaseRequestDispatchService.checkRequests(BaseRequestDispatchService.java:120)
        at com.emc.brs.vmdm.recovery.dispatch.BaseRequestDispatchService.lambda$startChecking$2(BaseRequestDispatchService.java:101)
        at java.base/java.util.concurrent.Executors$RunnableAdapter.call(Executors.java:539)
        at java.base/java.util.concurrent.FutureTask.runAndReset(FutureTask.java:305)
        at java.base/java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.run(ScheduledThreadPoolExecutor.java:305)
        at java.base/java.util.concurrent.ThreadPoolExecutor.runWorker(ThreadPoolExecutor.java:1136)
        at java.base/java.util.concurrent.ThreadPoolExecutor$Worker.run(ThreadPoolExecutor.java:635)
        at java.base/java.lang.Thread.run(Thread.java:840)

Cause

Palautusvirhe liittyy PowerProtect DD:ssä (DD) käyttöön otettuun NFS-kokoonpanoon. ESXi-isäntä ei pysty ottamaan NFSv4-vientiä käyttöön. Tämän artikkelin kirjoitushetkellä ESXi-isäntä voi ottaa käyttöön vain NFSv3- tai NFSv4.1-viennit.

 

Skenaario yksi:

DD:ssä on käytössä sekä NFSv3- että NFSv4-versio, ja NFSv4 on määritetty DD:n oletusversioksi.

DD NFS -versio käytössä 1

DD-komento näyttää oletuspalvelimen.

nfs option show

NFS-vaihtoehto Näytä tulos

 

Skenaario kaksi:

DD:ssä on käytössä vain NFSv4.

DD NFS -versio käytössä 2 


 

Resolution

Ota nykyinen DD NFS -kokoonpano mukaan joko käyttöön ja varmista, että DD:ssä on oletusarvoinen NFS-vientiversio NFSv3:een:
 

  1. Muodosta SSH-yhteys DD:hen.
  2. Vahvista nykyinen NFS-kokoonpanosi.
nfs option show

Esimerkki NFSv3 on käytössä, mutta NFS-oletuspalvelin on NFSv4.

NSFV4-oletus

  1. Jos tämä on pois käytöstä, ota NFSv3 käyttöön.
nfs disable version 3
    1. Jos NFS on versio 4, aseta NFSv3.
nfs option set default-server-version 3
  1. Suorita pikakäyttö tai tiedostotason palautus uudelleen.
     

Affected Products

PowerProtect Data Manager Appliance, PowerProtect Data Manager, PowerProtect Data Manager Software
Article Properties
Article Number: 000214971
Article Type: Solution
Last Modified: 18 Jul 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.