ECS: xDoctor: RAP163: Zdarzenie krytyczne dotyczące pamięci systemowej
Summary: Wystąpiło krytyczne zdarzenie pamięci systemowej, które wymaga sprawdzenia i wymiany modułów DIMM.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
xDoctor zgłasza krytyczne zdarzenie dotyczące pamięci systemowej, które wymaga sprawdzenia.
------------------------------------
ERROR - Critical System Memory Event
------------------------------------
Node = Nodes
Extra = {'Nodes': {'169.254.1.1': ['Memory #0x02 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory #0x03 - Uncorrectable ECC (UnCorrectable ECC | DIMMB1) (06/10/2023 08:45:16)', 'Memory Mmry ECC Sensor - Correctable ECC (11/26/2015 12:38:51)']}}
RAP = RAP163
Solution = KB 215723
Timestamp = 2023-07-10_170539
PSNT = CKMXXXXXXXXXXX @ 4.8-92.0Cause
UWAGA: Jeśli brakuje któregokolwiek z modułów DIMM lub w dziennikach zdarzeń systemowych (SEL) pojawi się zdarzenie Nie można go naprawić, należy wymienić moduły DIMM.
- Sprawdź dzienniki SEL, aby potwierdzić, że w węźle występują nienaprawialne błędy.
Polecenie: (Polecenie zdalne)
# sudo ipmitool -H <iDrac IP> -U root -P passwd -I lanplus sel elist
Polecenie: (Węzeł lokalny)
# sudo ipmitool sel elist
Example:
admin@node1:~> sudo ipmitool -H 192.XXX.2XX.107 -U root -P passwd -I lanplus sel elist 1 | 12/04/2021 | 07:29:19 | Event Logging Disabled SEL | Log area reset/cleared | Asserted 2 | 12/29/2021 | 23:00:29 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 3 | 01/26/2022 | 11:44:08 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 4 | 08/03/2022 | 18:31:45 | Power Supply PS Redundancy | Redundancy Lost | Asserted 5 | 08/03/2022 | 18:31:48 | Power Supply Status | Power Supply AC lost | Asserted 6 | 08/03/2022 | 18:43:14 | Power Supply Status | Power Supply AC lost | Deasserted 7 | 08/03/2022 | 18:43:22 | Power Supply PS Redundancy | Fully Redundant | Asserted 8 | 08/03/2022 | 18:51:27 | Power Supply PS Redundancy | Redundancy Lost | Asserted 9 | 08/03/2022 | 18:51:27 | Power Supply Status | Power Supply AC lost | Asserted a | 08/03/2022 | 19:02:03 | Power Supply Status | Power Supply AC lost | Deasserted b | 08/03/2022 | 19:02:14 | Power Supply PS Redundancy | Fully Redundant | Asserted c | 01/19/2023 | 05:38:27 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted d | 02/06/2023 | 02:10:25 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted e | 03/02/2023 | 17:12:15 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted f | 05/09/2023 | 15:56:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 10 | 05/09/2023 | 17:16:16 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 11 | 05/09/2023 | 20:57:41 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 12 | 05/09/2023 | 20:59:25 | Unknown #0x2e | | Asserted 13 | 05/09/2023 | 20:59:25 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted 14 | 05/11/2023 | 05:43:34 | Memory Mem ECC Warning | Transition to Critical from less severe | Asserted 15 | 06/10/2023 | 08:43:26 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 16 | 06/10/2023 | 08:45:16 | Unknown #0x2e | | Asserted 17 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted 18 | 06/10/2023 | 08:45:16 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMB1) | Asserted
- Sprawdź, czy w wyniku zdarzenia brakuje modułów DIMM.
Polecenie:
# sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
Example:
admin@node1:~> sudo dmidecode -t memory | grep "Locator\|Size" | grep -v "Cache\|Volatile\|Cache\|Logical\|Bank"
Size: No Module Installed <-- DIMM is missing
Locator: A1
Size: 16384 MB
Locator: A2
Size: No Module Installed
Locator: A3
Size: No Module Installed
Locator: A4
Size: No Module Installed
Locator: A5
Size: No Module Installed
Locator: A6
Size: No Module Installed
Locator: A7
Size: No Module Installed
Locator: A8
Size: 16384 MB
Locator: B1
Size: 16384 MB
Locator: B2
Size: No Module Installed
Locator: B3
Size: No Module Installed
Locator: B4
Resolution
Zbierz dane wyjściowe z powyższych poleceń i otwórz zgłoszenie serwisowe odwołujące się do 215723 bazy wiedzy, aby sprawdzić, czy moduł DIMM serwera jest wymieniony.
Jeśli moduł DIMM został pomyślnie wymieniony, xDoctor w wersji 4.8.92.0 lub nowszej wymaga wyczyszczenia dziennika SEL w węźle, którego dotyczy problem. Zatrzymuje dalsze alerty dotyczące tego wpisu dziennika.
Jeśli moduł DIMM został pomyślnie wymieniony, xDoctor w wersji 4.8.92.0 lub nowszej wymaga wyczyszczenia dziennika SEL w węźle, którego dotyczy problem. Zatrzymuje dalsze alerty dotyczące tego wpisu dziennika.
Przykład — czyszczenie dziennika zdarzeń systemu (SEL):
Wyślij zapytanie do kontrolera iDRAC, aby uzyskać dziennik zdarzeń systemowych i potwierdzić, że błąd występuje w danych wyjściowych.
Pamiętaj, że przed wyczyszczeniem dziennika SEL sprawdź, czy nie ma innych błędów, które należy rozwiązać. Zapisz również dziennik w /var/log/hardware Jak opisano w KB 49569.
W tym przykładzie 192.168.219.101 odpowiada adresowi IP kontrolera iDRAC węzła 1:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 01/06/2022 | 04:34:58 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted 2 | 02/03/2022 | 17:15:21 | Physical Security #0x73 | General Chassis intrusion () | Asserted 3 | 02/03/2022 | 17:15:28 | Physical Security #0x73 | General Chassis intrusion () | Deasserted 4 | 08/18/2023 | 01:44:01 | Memory #0x02 | Uncorrectable ECC (UnCorrectable ECC | DIMMA1) | Asserted
Wyczyść SEL:
admin@provo:~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel clear Clearing SEL. Please allow a few seconds to erase.
Sprawdź, czy lista została wyczyszczona:
admin@provo~> ipmitool -I lanplus -H 192.168.219.101 -U root -P passwd sel list 1 | 08/30/2023 | 12:56:55 | Event Logging Disabled #0x72 | Log area reset/cleared | Asserted